WARNING
Authorized supplier personnel normally accom- plish the connections for the ventilation system, electric and gas supplies, as arranged by the customer. Following these connections, the
Check the oven data plate (Figure
NOTE: The electric supply installation must satisfy the requirements of the appropriate statutory authority, such as the National Electrical Code (NEC), ANSI/NFPA70, (U.S.A.); the Canadian Electrical Code, CSA C22.2; the Australian Code AG601; or other applicable regula- tions.
A fused disconnect switch or a main circuit breaker (customer furnished) MUST be installed in the electric supply line for each oven; it is recommended that this switch/ circuit breaker have lockout/tagout capability. The electric supply connection must meet all national and local electrical code requirements. Copper is the recommended material for the electrical supply conductors.
IV. ELECTRIC SUPPLY FOR GAS HEATED OVENS
Power requirements for gas heated ovens are 208 - 240VAC,
The supply conductors must be of the size and material (copper) recommended to provide the current required; (refer to the data plate for the ampere specifications). The electric current rating for each conductor supplying a
ELECTRICAL
INLET
GAS INLET
Figure 2-11. Junction Connection Box
Figure 2-10. Typical Electric Oven Data Plate