Common coffee system care

The right display goes dark and the appliance is now lowering the perforator.

Remove capsule plate and change the capsule hopper

^Open the appliance door.

^Pull out the capsule plate.

,Do not reach up into the perforator opening. Danger of injury!

^Pull the rubber disc top, down and out.

^Insert the tool for removing the perforator up into the unit, a. Turn it to the left, b, to loosen and remove the perforator.

^Screw the new perforator firmly into the unit. The spring and ball bearing must be inserted in the perforator opening so that the ball bearing is on top.

^Insert the rubber disc from the bottom up (with the funnel pointing downwards).

^Insert the capsule plate and close the door.