Retaining plate C

Installation

Retaining plate C

Retaining plate C should only be used if dimension Y is greater than 14 3/8"

(365 mm.) It provides additional stability for the chimney extension.

^At a maximum distance of 14 3/8" (365 mm) from the ceiling hold retaining plate C against the wall and use the notches to align it with the center line. Mark the two drill holes.

^Drill two 1/8" (3 mm) holes into the wall.

^Secure retaining plate C with two 5 x 40 mm screws.

Attaching the canopy

^Hang the canopy on the angled brackets on retaining plate A.

^Secure the canopy with 5 x 40 mm screws into each drilled hole.