Miele DA218, DA211 Recirculation connection, Attaching the chimney extension, Installation

Models: DA211 DA218

1 44
Download 44 pages 6.17 Kb
Page 36
Image 36
Recirculation connection

Installation

Recirculation connection

Recirculation mode is used when venting to the outside of the building is not possible.

^Slide the diverter on to the brackets of plate B.

^Slip the hose clamps over the flex hose onto the diverter and the motor assembly exhaust connection. Once in place, tighten the hose clamps.

Active charcoal filters must be used in the recirculation mode.

Attaching the chimney extension

The use of a chimney extension, allows the hood to be installed at various distances from the ceiling.

NOTE: The extension must be intalled in relationship to the method of venting; Extraction or Recirculation.

Recirculation

Air extraction

The extension piece has vented openings on one end.

These vents are required for recir- culation mode and will be closest to the ceiling when installed.

For air extraction, the vents are not required and are covered by the chimney.

36

Page 36
Image 36
Miele DA218, DA211 installation instructions Recirculation connection, Attaching the chimney extension, Installation