Miele DA211, DA218 Operation, Turning on the fan, Selecting the power level, Intensive setting

Models: DA211 DA218

1 44
Download 44 pages 6.17 Kb
Page 11
Image 11
Operation

Operation

Turning on the fan

Selecting the power level

^ Press the On/Off button.

^ Use the _ controls to select the

The fan runs at power level "2".

desired power level.

& =increases the fan speed

The On/Off indicator lights.

 

$ =decreases the fan speed

 

Level "1" to "3" (green indicators) are

 

usually sufficient for normal cooking.

Intensive setting

Level "4" (yellow indicator) should be used for a short period when frying or cooking food with a strong aroma.

Fan performance

The maximum air flow capacity is

625 cfm. Factors such as narrow duct diameter and bends will affect this value.

Level 1 operates at 40% capacity

Level 2 operates at 60% capacity

Level 3 operates at 80% capacity

Level 4 operates at 100% capacity

There will also be a slight decrease in airflow for hoods operated in recirculation mode due to the active charcoal filter.