Miele DA 2250 EXT Technical data, Fan performance, Special accessory for recirculation mode

Models: DA 2250 DA 2250 EXT DA 2210 DA 2270 DA 2270 EXT

1 40
Download 40 pages 6.7 Kb
Page 38
Image 38
Technical data

Technical data

Total connected load*

DA 2250, DA 2270. . . . . . . . . . . . 300 W DA 2210. . . . . . . . . . . . . . . . . . . . 780 W

– Fan motor

DA 2250, DA 2270 . . . . . . . . . . 200 W DA 2210 . . . . . . . . . . . . . . . 2 x 290 W

– Hob lighting

DA 2250, DA 2270 . . . . . . . . 2 x 50 W DA 2210 . . . . . . . . . . . . . . . . 4 x 50 W

Voltage . . . . . . . . . . . . . . . . . AC 230 V

Frequency . . . . . . . . . . . . . . . . . . 50 Hz

Fuse rating GB . . . . . . . . . . . . . . . . . 5 A

AUS, NZ:

Plug rating . . . . . . . . . . . . . . . . . . . 10 A

Test marks . . . . . . . . . . Electrical safety

. . . . . . . . . . . . . . . . . . . . . . C-Tick Mark

Electrically suppressed according to AS/NZS 1044

Electrical cable length . . . . . . . . . 1.5 m

Weight

DA 2250 . . . . . . . . . . . . . . . . . . . . . 8 kg DA 2250 EXT . . . . . . . . . . . . . . . . 5.5 kg DA 2270. . . . . . . . . . . . . . . . . . . . 9.5 kg DA 2270 EXT . . . . . . . . . . . . . . . . . 7 kg DA 2210 . . . . . . . . . . . . . . . . . . . . 16 kg

Fan performance*

Extraction power according to EN 61591

DA 2250, DA 2270:

Extraction system ￿ 150 mm

Level I . . . . . . . . . . . . . . . . . . . 200 m3/h Level II. . . . . . . . . . . . . . . . . . . 300 m3/h Level III . . . . . . . . . . . . . . . . . . 400 m3/h

Level IV Intensive Setting . . . . 640 m3/h

Recirculation with charcoal filter:

Level I . . . . . . . . . . . . . . . . . . . 140 m3/h

Level II. . . . . . . . . . . . . . . . . . . 240 m3/h

Level III . . . . . . . . . . . . . . . . . . 360 m3/h

Level IV Intensive Setting . . . . 550 m3/h

DA 2210:

Extraction system 2 x ￿ 150 mm

Level I . . . . . . . . . . . . . . . . . . . 650 m3/h Level II. . . . . . . . . . . . . . . . . . . 950 m3/h Level III . . . . . . . . . . . . . . . . . 1250 m3/h

Level IV Intensive Setting . . . 1850 m3/h

Recirculation with charcoal filter:

Level I . . . . . . . . . . . . . . . . . . . 600 m3/h

Level II. . . . . . . . . . . . . . . . . . . 900 m3/h

Level III . . . . . . . . . . . . . . . . . 1200 m3/h

Level IV Intensive Setting . . . 1550 m3/h

Special accessory for recirculation mode:

Conversion kit DUU 151

2 kits are required for the DA 2210

Miele charcoal filter pack DKF 15-1 (each pack contains 2 filters)

2 packs are required for the DA

2210

* For EXT models,

the rated load and extraction power will depend on the type of external motor fitted.

Length of connection cable to external motor. . . . . . . . . . . . . . . . . . . . . . . 1.9 m