Note

To allow proper filling of the Rinse Aid Dispenser; Rinse Aid should only be added with the door in the fully open position.

4.4Heaters

During the main wash and final rinse portions of a wash cycle, the water is heated to the programs specified temperature before advancing to the next step in the program (i.e.Thermal Stop). The water is heated using one of two systems:

4.4.1Wash Cavity Heating Element

Figure 4-2:Cavity Style Heater Element

The Heating Element is mounted just off the floor of the wash cavity. When powered (120 VAC) the element radiates heat thereby heating the surrounding and circulating water. The temperature of

the water is monitored by the Temperature Sensor, mounted in the Sump.

Heating Element switching is performed by the electronic via a Relay. The relay (when energized) closes contacts to provide the Heater Element with 120VAC. A Temperature Limiter mounted with the element provides protection by opening up the circuit should the temperature become to high.