4.6Pulsed Heating - Operation

In certain programs the heating may be operated at full power until a water temperature of 77°F is reached; then power is applied in pulses. This extends the heating time and allows enzyme-containing detergents to develop their full cleaning potential.

The pulsed heating operates as follows:

1 min heater element on.

1 min heater element off.

The number of pulse cycles is limited to a maximum of 11. If the programs specified temperature has not been reached, the heating resumes using full power. Once the programs temperature has been reached, the electronic unit advances to the next step in the program. If the temperature cannot be reached (i.e. heater failure) within a specified time, the program will advance; and a heating fault is stored in the electronic.

4.7Temperature Protection

The Flow-through Heater uses two (2) Temperature Limiters (2F2) mounted on the body of the Flow-Through Heater. The Temperature Limiters are designed to open the circuit should the temperature become too high. When the temperature falls, the Temperature Limiters do not reset automatically and must be reset manually (via the red button on the back of the device).

Additional protection is provided by the Electronic, which switches the appliance off and stores an F4 fault code, should the temperature exceed 194°F (90°C) – as determined by the Temperature Sensor.

4.8Static Drying

The Static Drying System uses no electrical and / or mechanical components to assist in drying. With this system the final rinse water is heated to 154°F (68°C) (not the usual 150°F / 67°C). The dishwasher cabinet is made of stainless steel; and conducts the heat generated during the final rinse. As the final rinse ends this stored thermal energy radiates and assists in the drying.