G600 & G800 Electronic Dishwashers
Technical Information
4.18Condenser Drying (UKT)
Does not apply to all dishwasher models
4.18.1Operation
An air inlet port is located on the back / left area of the cavity ceiling. An air duct is fitted to the port and attaches to the Condenser Assembly.
During the Drying portion of a program, moist air within the cabinet is drawn through the Condenser Assembly via the Condenser Fan (M2). As the cabinet air passes the Cold Water Reservoir (inside the condenser) water vapor forms and exits the condenser (as water) via the port on the left wall of the cabinet.
The cooling bank within the Condenser Assembly utilizes water from the intake / softening system controlled by the electronic via the Condenser Control Valve (Y6).
4.18.2Technical Data
Control valve (Y6) AC 120 Hz
Cold Water Reservoir 750 ml