Miele M.-Nr. 09 805 980 Operation Automatic mode, Cooking with Con@ctivity 2.0 Automatic mode

Models: M.-Nr. 09 805 980

1 56
Download 56 pages 20.7 Kb
Page 18
Image 18
Operation (Automatic mode)

Operation (Automatic mode)

When Con@ctivity 2.0 is active, the hood always operates in Automatic mode (see "Activating Con@ctivity 2.0").

See "Cooking without Con@ctivity 2.0" for information on manually operating the hood.

Cooking with Con@ctivity 2.0 (Automatic mode)

Turn on a burner to the desired power setting.

The hood lighting will come on.

After a few seconds, the fan will come on, briefly operating at power level 2 before immediately switching to level 1.

The hood selects the fan level automat‐ ically during cooking.

This level is determined by the total output of the cooktop, i.e. the number of burners in operation and the power settings selected.

If you select a higher power setting on the cooktop or switch on multiple burners, the hood will switch to a higher fan level.

If you select a lower power setting on the cooktop or turn off a burner, the hood will accordingly switch to a low‐ er fan level.

Reaction time

Changing the power setting on the cooktop does not lead to an immediate increase or decrease in cooking vapors. For this reason, the hood reacts with a slight delay.

Delays can also result from the fact that the cooktop transmits the information to the hood in intervals.

The reaction time can vary from a few seconds to a couple of minutes.