Distance between cooktop and ventilation hood (S)

Installation

fA power cord is required to connect the hood to the socket in the ceiling. With extraction mode flexible ducting is also required.

Exhaust connection  6" (150 mm)

Distance between cooktop and ventilation hood (S)

Provided a larger distance is not given by the manufacturer of the cooktop, fol‐ low the minimum safety distances between a cooktop and the bottom of the hood.

Please also observe the information contained in the "IMPORTANT SAFETY IN‐ STRUCTIONS" section.

 

Minimum distance S

 

 

 

Cooking appliance

Miele appli‐

Non-Miele ap‐

 

ance

pliance

 

 

 

Electric/Induction cooktop

24" (610 mm)

 

 

Electric grill, deep fat fryer (electric)

26" (660 mm)

 

 

 

Multi-burner gas cooktop

26" (660 mm)

30" (760 mm)

≤ 43,000 BTU/hr (12.6 W),

 

 

no burner > 15,000 BTU/hr (4.5 kW).

 

 

Multi-burner gas cooktop

30" (760 mm)

≤ 73,800 BTU/hr (21.6 W),

 

 

no burner > 16,500 BTU/hr (4.8 kW)

 

 

Multi-burner gas cooktop

Not possible

> 73,800 BTU/hr (21.6 W),

 

 

or one of the burners > 16,500 BTU/hr (4.8 kW)

 

 

Single-burner gas cooktop

26" (660 mm)

30" (760 mm)

≤ 20,500 BTU/hr (6 kW)

 

 

Single-burner gas cooktop

30" (760 mm)

≤ 27,600 BTU/hr (8.1 kW)

 

 

Single-burner gas cooktop

Not possible

> 27,600 BTU/hr (8.1 kW)

 

 