Refer to Section A for millivolt appliances and Section B for electronic appliances. The gas valve is set in place and
1.
2. If
3. Wire the control switch within the millivolt control circuit using the 15 feet of 2 conductor wire supplied with the unit.
Note: The supplied 15 feet of 2 conductor wire has one end of each conductor connected to the gas valve circuit and the other end of each conductor placed loose inside the lower compartment of the unit.
Caution: do not connect the optional wall switch to a 120V power supply.
4.If an optional control switch is installed, turn the
10
Millivolt Wiring Diagram
If any of the original wire as supplied must be replaced, it must be replaced with Type AWM 105° C – 18 GA. wire.
SWITCHLIMIT |
| White |
|
| TP | TH | |
|
|
| TH TP |
|
| Thermopile |
|
| White | Black | Field Wired |
|
| ||
|
|
|
Factory Wired
*OPTIONAL
SWITCH OR OPTIONAL THERMOSTAT
OR OPTIONAL REMOTE RECEIVER
*Turn the
switch to the OFF position if an optional
control switch is installed.
Schematic Representation Only
Figure 16
B. Electronic Wiring(also see Figure 18 on page 11 )Note: The electronic appliance must be connected to the main power supply.
1. Route a
2.Open the control compartment access panel, by actuating the
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
3.Remove the bottom control compartment access panel by compressing the spring- loaded hinge pin on the left side until it disengages from the left cabinet panel hole. Pull the panel away from the fire- place. See Figure 20 on page 12.
4.Remove the modesty panel by pulling the bottom edge of the modesty panel out of
the locking slots of the cabinet bottom. Then tilt the top edge at a 45° angel and
lift out. Remove the modesty panel care- fully, so that none of the wires become loose or disconnected.
5. Remove the outlet receptacle by removing the two securing screws. See Figure
17.(The left and right designations used here are reversed in EBVCR applications.)
6. Install a
7. Connect the power supply wires to the receptacle as shown in Figure 18 on page 11.
8. Connect the ground supply wire and the green wire attached to the outlet receptacle's green ground screw.
9.