Step 4. FIELD WIRING

Refer to Section A for millivolt appliances and Section B for electronic appliances. The gas valve is set in place and pre-wired at the factory on both models.

A. Millivolt Wiring (See Figure 16 )

1. Appliance-mounted ON/OFF burner control switch (rocker switch) is factory installed in the modesty panel. Optional wall-mounted switch, thermostat, or one of the optional remote control kits may also be used.

2. If wall-mounted ON/OFF control or thermostat is selected, mount it in a convenient location on a wall near the fireplace.

3. Wire the control switch within the millivolt control circuit using the 15 feet of 2 conductor wire supplied with the unit.

Note: The supplied 15 feet of 2 conductor wire has one end of each conductor connected to the gas valve circuit and the other end of each conductor placed loose inside the lower compartment of the unit.

Caution: do not connect the optional wall switch to a 120V power supply.

4.If an optional control switch is installed, turn the appliance-mounted ON/OFF burner control switch to the OFF position.

10

Millivolt Wiring Diagram

If any of the original wire as supplied must be replaced, it must be replaced with Type AWM 105° C – 18 GA. wire.

SWITCHLIMIT

 

White

 

 

TP

TH

 

 

 

TH TP

 

 

Thermopile

 

 

White

Black

Field Wired

 

 

 

 

 

Factory Wired

APPLIANCE-MOUNTED ON/OFF SWITCH

*OPTIONAL WALL-MOUNTED ON/OFF

SWITCH OR OPTIONAL THERMOSTAT

OR OPTIONAL REMOTE RECEIVER

*Turn the appliance-mounted ON/OFF burner control

switch to the OFF position if an optional

control switch is installed.

Schematic Representation Only

Figure 16

B. Electronic Wiring(also see Figure 18 on page 11 )

Note: The electronic appliance must be connected to the main power supply.

1. Route a 3-wire 120Vac 60Hz 1ph power supply to the appliance junction box.

2.Open the control compartment access panel, by actuating the spring-loaded magnetic catches securing the panel, gently depressing the outer top corners of the panel until the catches "pop" the panel free and allowing it to swing out and down to open.

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

3.Remove the bottom control compartment access panel by compressing the spring- loaded hinge pin on the left side until it disengages from the left cabinet panel hole. Pull the panel away from the fire- place. See Figure 20 on page 12.

4.Remove the modesty panel by pulling the bottom edge of the modesty panel out of

the locking slots of the cabinet bottom. Then tilt the top edge at a 45° angel and

lift out. Remove the modesty panel care- fully, so that none of the wires become loose or disconnected.

5. Remove the outlet receptacle by removing the two securing screws. See Figure

17.(The left and right designations used here are reversed in EBVCR applications.)

6. Install a field-provided strain relief in the cabinet knockout opening for the protection of the power supply wires.

7. Connect the power supply wires to the receptacle as shown in Figure 18 on page 11.

8. Connect the ground supply wire and the green wire attached to the outlet receptacle's green ground screw.

9. Appliance-mounted ON/OFF burner control switch (rocker switch) is factory installed in the modesty panel. Optional wall-mounted switch, thermostat, or one of the optional remote control kits may also be used.