WARNING: THIS CONVERSION KIT SHALL BE INSTALLED BY A QUALIFIED SERVICE AGENCY IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS AND ALL APPLICABLE CODES AND REQUIREMENTS OF THE AUTHORIZED AGENCY HAVING JURISDICTION. IF THE INFORMATION IN THESE INSTRUCTIONS IS NOT FOLLOWED EX- ACTLY, A FIRE, EXPLOSION OR PRODUCTION OF CARBON MONOXIDE MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. THE INSTALLATION IS NOT PROPER AND COMPLETE UNTIL THE OPERATION OF THE CONVERTED APPLIANCE IS CHECKED AS SPECIFIED IN THE OWNER INSTRUCTIONS SUPPLIED WITH THE KIT. THE QUALIFIED SERVICE AGENCY PERFORMING THIS INSTALLATION ASSUMES RESPONSIBILITY FOR THIS CONVERSION.
AVERTISSEMENT: CET ÉQUIPEMENT DE CONVERSION SERA INSTALLÉ PAR UNE AGENCE QUALIFIÉE DE SERVICE CONFORMÉMENT AUX INSTRUCTIONS DU FABRICANT ET TOUTES EXIGENCES ET CODES APPLICABLES DE L'AUTORISÉS AVOIR LA JURIDICTION. SI L'INFORMATION DANS CETTE INSTRUCTION N'EST PAS SUIVIE EXACTEMENT, UN FEU, EXPLOSION OU PRODUCTION DE PROTOXYDE DE CARBONE PEUT RÉSULTER LE DOMMAGES CAUSER DE PROPRIÉTÉ, PERTE OU BLESSURE PERSONNELLE DE VIE. L'AGENCE QUALIFIÉE DE SERVICE EST ESPONSABLE DE L'INSTALLATION PROPRE DE CET ÉQUIPMENT. L'INSTALLATION N'EST PAS PROPRE ET COMPLÉTE JUSQU'À L'OPÉRATION DE L'APPAREIL CONVERTI EST CHÉQUE SUIVANT LES CRITÈRES ÉTABLIS DANS LES INSTRUCTIONS DE PROPRIÉTAIRE PROVISIONNÉES AVEC L'ÉQUIPEMENT.
THE CONVERSION SHALL BE CARRIED OUT IN ACCORDANCE WITH THE REQUIREMENTS OF THE PROVINCIAL AUTHORITIES HAVING JURISDICTION AND IN ACCORDANCE WITH THE REQUIREMENTS OF THE
LA CONVERSION DEVRA ÊTRE EFFECTUÉE CONFORMÉMENT AUX RECOMMANDATIONS DES AUTORITÉS PROVINCIALES AYANT JURIDICTION ET CONFORMÉMENT AUX EXIGENCES DU CODE D'INSTALLATION CAN1- B149.1 ET.2.
Gas conversion kits are available to convert your appliance from the use of one type of gas to the use of another. These kits contain all the necessary components needed to complete the task including labeling that must be affixed to ensure safe operation.
Kit part numbers are listed here and the following steps detail the conversion procedure.
Step 1. Turn off the gas supply to the appliance.
a.Open the control compartment access panel, by actuating the
b.Remove the bottom control compartment access panel by compressing the spring- loaded hinge pin on the left side until it disengages from the left cabinet panel hole. Pull the panel away from the fire- place. See Figure 20 on page 12.
c.Remove the modesty panel by pulling the bottom right corner of the modesty panel out slightly to disengage the
d.Locate the latch at the top of the control compartment. To disengage the latch from the bottom
e.Swing the bottom of the door out and raise it slightly to lift the top flange of the door frame away from the appliance.
Step 2. Carefully remove the logs. Exercise care as not to break the logs.
Step 3. Referring to Figure 29 on page 17, remove the burner.Models No. | Unit Type | Catalog No. |
|
|
|
EBVST | millivolt | H2198 |
EBVPF | electronic | H2200 |
|
|
|
Natural To Propane Gas Conversion Kit
Models No. | Unit Type | Catalog No. |
|
|
|
EBVCR | millivolt | H2198 |
EBVCL | electronic | H2200 |
|
|
|
Model No. | Unit Type | Catalog No. |
|
|
|
EBVST | millivolt | H2199 |
EBVPF | electronic | H2201 |
|
|
|
Propane to Natural Gas Conversion Kit
Model No. | Unit Type | Catalog No. |
|
|
|
EBVCR | millivolt | H2203 |
EBVCL | electronic | H2205 |
|
|
|
16