| TYPICAL LOCATIONS | |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| *When | |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
| Corner | - Left |
|
| |||||||||
|
|
|
|
|
| Corner - Right |
|
|
|
| installed with one side flush | |||||||||||||
|
|
|
|
|
|
|
|
|
| (EBCL |
|
| with a wall,opposite wall must | |||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| n o t e x t e n d b e y o n d e i t h e r | |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| viewing side of the fireplace. | ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Bay |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
| Peninsula |
|
|
|
| (EBBAY) |
|
|
| **When | |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| installed in the middle of a room, | |||||
|
|
|
|
|
|
|
|
|
|
|
| do not extend side walls beyond | ||||||||||||
|
|
|
|
|
|
|
|
|
|
|
| either viewing side of the fireplace. | ||||||||||||
|
|
|
|
|
|
|
|
|
|
| one side flush with a wall |
| ||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Figure 2 |
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| APPLIANCE AND VENT CLEARANCES | ||||||||
|
|
|
| WARNING: CHILDREN AND ADULTS |
|
|
| |||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||
|
|
|
| SHOULD BE ALERTED TO THE HAZARDS |
|
|
| The appliance is approved with zero clear- | ||||||||||||||||
|
|
|
| OF HIGH SURFACE TEMPERATURES. USE |
|
|
| ance to combustible materials on all sides (as | ||||||||||||||||
|
|
|
| CAUTION AROUND THE APPLIANCE TO |
|
|
| detailed in Table 2), with the following excep- | ||||||||||||||||
|
|
|
| AVOID BURNS OR CLOTHING IGNITION. |
|
|
| tion: When the unit is installed with one side | ||||||||||||||||
|
|
|
| YOUNG CHILDREN SHOULD BE CARE- |
|
|
| flush with a wall, the wall on the other side of | ||||||||||||||||
|
|
|
| FULLY SUPERVISED WHEN THEY ARE IN |
|
|
| the unit must not extend beyond the front | ||||||||||||||||
|
|
|
|
|
|
| edge of the unit. |
|
| |||||||||||||||
|
|
|
| THE SAME ROOM AS THE APPLIANCE. |
|
|
|
|
| |||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
| WARNING: DO NOT PLACE CLOTHING |
|
|
|
|
|
| BACK |
| 1/2 in. (13 mm) |
| ||||||||||
|
|
|
| OR OTHER FLAMMABLE MATERIALS |
|
|
|
|
|
|
| 0 in. (0 mm) spacers |
| |||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||
|
|
|
| ON OR NEAR THIS APPLIANCE. |
|
|
|
|
|
|
|
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
| SIDES |
| 1/2 in. (13 mm) |
| |||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 0 in. (0 mm) spacers |
| |||
|
|
|
| AVERTISSEMENT: SURVEILLER LES |
|
|
|
|
|
|
|
|
|
|
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||
|
|
|
|
|
| TOP SPACERS |
| 0 in. (0 mm) |
| |||||||||||||||
|
|
|
| ENFANTS. GARDER LES VÊTEMENTS, |
|
|
|
|
|
| ||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||
|
|
|
| LES MEUBLES, L'ESSENCE OU AUTRES |
|
|
|
|
|
| FLOOR |
| 0 in. (0 mm) |
| ||||||||||
|
|
|
| LIQUIDES À VAPEUR INFLAMMABLES À |
|
|
|
|
|
|
|
|
|
|
|
| ||||||||
|
|
|
|
|
|
| From Bottom |
|
|
| ||||||||||||||
|
|
|
| COTE DE L'APPAREIL. |
|
|
|
|
|
|
|
|
|
| ||||||||||
|
|
|
|
|
|
|
|
|
|
| of Unit to |
| 64 in. (1626 mm) |
| ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
| These appliances are equipped with an inte- |
|
|
|
|
|
| Ceiling |
|
|
| ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||
|
|
|
| gral combustion air door and actuator arm. |
|
|
|
|
|
| VENT |
| 1 in. (25.4 mm) |
| ||||||||||
|
|
|
| Combustion air kits are optional.Install as |
|
|
|
|
|
|
|
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
| SERVICE CLEARANCES |
| ||||||||||||||
|
|
|
| shown in Step 6 on page 12. |
|
|
|
|
|
|
|
|
|
| ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| LOCATION |
|
|
|
|
|
|
|
| VIEWING |
|
|
| ||||||||
|
|
|
| In selecting the location, the aesthetic and func- |
|
|
|
|
|
| SIDES - |
| 3 Feet. (0.9 meters) |
| ||||||||||
|
|
|
|
|
|
|
| (FRONT, BACK |
|
| ||||||||||||||
|
|
|
| tional use of the appliance are primary concerns. |
|
|
|
|
|
|
| |||||||||||||
|
|
|
|
|
|
|
|
| OR SIDE) |
|
|
| ||||||||||||
|
|
|
| However, vent system routing to the outside |
|
|
|
|
|
|
|
| ||||||||||||
|
|
|
| atmosphere and access to the fuel supply are |
|
|
| Table 2 |
|
|
|
|
| |||||||||||
|
|
|
| also important. Consideration should be given to |
|
|
|
|
|
|
|
| ||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||
|
|
|
| traffic ways, furniture, draperies, etc., due to high |
|
|
|
|
|
|
|
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||
|
|
|
| surface temperatures (Figure 2 ). The location |
|
|
| In addition, when the unit is installed in the | ||||||||||||||||
|
|
|
| should also be free of electrical, plumbing or |
|
|
| middle of a room, the side walls surrounding | ||||||||||||||||
|
|
|
| other heating/air conditioning ducting. |
|
|
| the unit must not extend beyond the front or | ||||||||||||||||
|
|
|
| The appliance should be mounted on a fully |
|
|
| rear edge of the unit. See Figure 2. | ||||||||||||||||
|
|
|
|
|
|
| Vertical Vent Termination Clearances | |||||||||||||||||
|
|
|
| supported base extending the full width and |
|
|
| |||||||||||||||||
|
|
|
| depth of the unit. The appliance may be located |
|
|
| Gas Vent Rule – Gas vent caps are not permit- | ||||||||||||||||
|
|
|
| on or near conventional construction materi- |
|
|
| |||||||||||||||||
|
|
|
| als. However, if installed on combustible mate- |
|
|
| ted within 8 feet (2.4 mm) of a vertical wall or | ||||||||||||||||
|
|
|
| rials, such as carpeting, vinyl tile, etc., a metal |
|
|
| similar obstruction. |
|
| ||||||||||||||
|
|
|
| or wood barrier covering the entire bottom |
|
|
|
|
|
|
|
|
|
|
|
| ||||||||
4 |
|
|
| surface must be used. |
|
|
|
|
|
|
| NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. | ||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||
|
|
|
|
|
Gas vent caps that are located 8' or more from a portion of a building which extends at an angle greater than 45° upward from the horizontal may terminate in accordance with (Fig- ure 3 ), provided that in no case shall any discharge opening on the cap be less than 2' (610 mm) horizontally from the roof surface (National Fuel Gas Code ANSI Z223.1 (NFPA 54) 7.6.2) (CAN/CGA B149).
These instructions should be used as a guideline and do not supersede local codes in any way.
Multiple Terminations – These appliances may vent adjacent to and at the same level with any other gas appliances (including direct
Note: Venting terminals shall not be recessed into a wall or siding.
X
12
Roof Pitch is X/12
Minimum Height from Roof to Lowest Discharge Opening
| Minimum Height | ||
Roof Slope | from Roof to Lowest | ||
Discharge Opening | |||
| |||
|
|
| |
| Feet | Meters | |
|
|
| |
Flat to 6/12 | 1' 0" | 0.3 | |
|
|
| |
Over 7/12 to 9/12 | 2' 0" | 0.6 | |
|
|
| |
Over 10/12 to 12/12 | 4' 0" | 1.2 | |
|
|
| |
Over 13/12 to 16/12 | 6' 0" | 1.8 | |
|
|
| |
Over 17/12 to 21/12 | 8' 0" | 2.4 | |
|
|
|
Figure 3
TYPICAL INSTALLATION SEQUENCE
The typical sequence of installation follows, however, each installation is unique resulting in variations to those described.