10ft.Minimum

60degrees max.

12 ft. Minimum

Slip the first 6 inch (152 mm) section of B- Vent over the fireplace flue outlet and secure with four sheetmetal screws (# 8 or larger), and install the remainder of the B-Vent to the outside. Minimum overall height of the vent system and appliance must be 10' (2.54 m) vertical - no offset (see Figure 6 ); or 12' (3.7

m)when an offset up to 60 degrees from the vertical is used - this offset may start at the fireplace flue collar (see Figure 7 ). The maximum overall height of the vent system and appliance should not exceed 40 feet.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Install the B-vent system in accordance with

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

the vent manufacturer's instructions.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAUTION: THIS APPLIANCE CANNOT BE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VENTED HORIZONTALLY.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note: Refer to the vent manufacturers in-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

stallation instructions for variations of vent-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ing techniques. If common venting of sev-

Figure 6

Figure 7

eral units is contemplated, it should be dis-

cussed with an architect and the local Build-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ing Department.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Do not place insulation materials within 1 in.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

of the gas vent system.
FIREPLACE FRAMING SPECIFICATIONS

EBVST (See-Through)

Minimum Framing

Stud size is 2 x 4

inches (millimeters)

Gas Line

Center of gas line is 3 in. (76 mm) up from floor.

6¹⁄₄

(159)*41¹⁄₂

(1054)

22³⁄₄**

41¹⁄₂ (578)

(1054)

*This dimension can be reduced to 41 inches (1041 mm). This results in 0 in. (0 mm) clearance between framing and unit framing spacers. (The 41¹⁄₂ in. dimension permits easier fireplace installation, if unit is installed after framing is erected.)

**Based on 5/8” drywall. Use 23” for 1/2” drywall.

Figure 8

EBVPF
(Peninsula)

Minimum Framing

 

Stud size is 2 x 4

inches (millimeters)

Gas Line

Center of gas line is 3 in. (76 mm) up from floor.

6¹⁄₄

*41¹⁄₂

(159)

(1054)

22³⁄₄**

40¹⁄₈ (578)

(1019)

*This dimension can be reduced to 41 inches (1041 mm). This results in 0 in. (0 mm) clearance between framing and unit framing spacers. (The 41¹⁄₂ in. dimension permits easier fireplace installation, if unit is installed after framing is erected.)

**Based on 5/8” drywall. Use 23” for 1/2” drywall.

Figure 9

6

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.