TABLE OF CONTENTS |
|
| |
Packaging ........................................ | page | 2 | |
Introduction ..................................... | page | 2 | |
General Information ......................... | page | 2 | |
Massachusetts and New York |
|
| |
Requirements ................................ | page | 2 | |
Location | .......................................... | page | 4 |
Appliance and Vent Clearances ....... | page | 4 | |
Vent Termination Clearances ........... | page | 4 | |
Typical Installation Sequence .......... | page | 4 | |
Detailed Installation Steps ............... | page | 5 | |
Step 1. | Framing ............................. | page | 5 |
Step 2. | Routing Gas Line ............... | page | 5 |
Step 3. | Install the Venting System . page | 5 | |
Fireplace Specifications ................... | page | 6 | |
Step 4. | Field Wiring ....................... | page | 10 |
Step 5. | Connecting Gas Line .......... | page | 11 |
Step 6. | Outside Air Kit Installation . page | 12 | |
Step 7. | Installing Logs ................... | page | 13 |
Step 8. | Checking Unit Operation ..... | page | 13 |
Step 9. | Installing Glass Enclosure |
|
|
Panels .......................................... | page | 13 | |
Step 10. | Burner Adjustment ............ | page | 14 |
Step 11. | Spillage Test and Safety |
|
|
Limit Switch Operation ................ | page | 14 | |
Step 12. | Hood Installation ............... | page | 15 |
Finishing Requirements ................... | page | 15 | |
Cold Climate Insulation .................... | page | 15 | |
Gas Conversion Kits .................. | page 16 |
This installation manual will help you achieve a safe, efficient and dependable installation for your appliance and vent system.
Please read and understand these instructions before beginning your installation.
DO NOT ATTEMPT TO ALTER OR MODIFY THE CONSTRUCTION OF THE APPLIANCE OR ITS COMPONENTS. ANY MODIFICATION OR ALTERATION MAY VOID THE WARRANTY, CERTIFICATION AND LISTINGS OF THIS UNIT.
2
The assembled vented gas fireplace is packaged with:
1 - one log set located within the firebox.
2 - one plastic bag containing the literature package, which consists of the homeowner's manual, installation instructions, log placement guide and warranty, 8 (EBVST), 4 (EBVPF, EBVCL and EBVCR) nailing flanges; plastic bag is located on top of the fireplace.
3 - two hoods (EBVST, EBVCR, EBVCL), or three hoods (EBVPF) taped to the top of the fireplace.
4 - one plastic bag of glowing embers, one plastic bag of decorative volcanic stone and one bag of vermiculate is located in the bottom compartment.
INTRODUCTIONThese vented gas fireplaces are designed for residential applications. They must be installed with approved
The millivolt appliances are designed to operate on either natural or propane gas. A millivolt gas control valve with piezo ignition system provides safe, efficient operation. If any optional accessories which require electrical power are being installed, the electrical power must be provided at the time of appliance installation.
Electronic appliances are designed to operate on natural or propane gas. An electronic intermittent pilot ignition system provides safe, efficient operation. External electrical power is required to operate these units.
These appliances comply with National Safety Standards and are tested and listed by Omni- Test Laboratories (Report No.
These appliances may be used for bedroom installations in the United States and are listed accordingly. These units may not be installed in bedrooms in Canada.
Installation must conform to local codes. In the absence of local codes, installation must comply with the current National Fuel Gas Code, ANSI Z223.1. (In Canada, the current
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
These appliances are approved for installation in the following USA locations listed in the following:
Massachusetts:Installation of these fireplaces are approved for installation in the US state of Massachu- setts if the following additional requirements are met-
•Installation and repair must be done by a plumber or gas fitter licensed in the Common- wealth of Massachusetts.
•The flexible gas line connector used shall not exceed 36 inches (92 centimeters) in length.
•The individual manual
Installation of these fireplaces are approved for installation in New Your City in the US state of New York, if the following additional requirements are met-
•An outside air kit
WARNING: THESE FIREPLACES ARE VENTED DECORATIVE GAS APPLIANCES. DO NOT BURN WOOD OR OTHER MATERIAL IN THESE APPLIANCES.
Note: Installation and repair should be performed by a qualified service person. The appliance should be inspected annually by a qualified professional service technician. More frequent inspections and cleanings may be required due to excessive lint from carpeting, bedding material, etc. It is imperative that the control compartment, burners and circulating air passage ways of the appliance be kept clean.
TYPICAL INSTALLATIONOffset VentingVertical VentingFigure 1