Note - The air shutter for the burner primary air opening is
Figure 25.
*Air Shutter
BurnerOpening
Venturi
Tube
Orifice
Millivolt Shown
*Note - Do Not Adjust the
This appliance is equipped with a
A- To access the blocked flue safety switch when top radiant panel is not covered with non- combustible material:
1- Lift up and remove top radiant panel/eyebrow assembly on the control side of unit.
2- Reach between the cabinet side and the firebox side wall and locate the blocked flue safety switch.
3- Push the red reset button on the switch.
The applilance should then relight and remain lit. If this does not occur, turn off the appliance and call a qualified service technician.
B- To access the blocked flue safety switch when top radiant panel is covered with non- combustible material:
NOTE - This procedure should only be performed by a qualified service technician.
Important - Turn electrical power off before beginning this procedure.Natural Gas
Propane
1 - Lower bottom hinged panel on the control side of the fireplace. Remove the modesty panel |
Models inches
Gas
and glass enclosure panel as described on page 5, Steps 3, 4, 5 and 6 under "Detailed Installation |
inches
Steps" heading. |
(mm)
EBVST
(mm)
2 - Remove the side baffle securing screws (5) and then remove the baffle. |
3 - Remove the safety switch bracket securing screws (2), and pull the switch/bracket assembly |
through the side panel slot. |
EBVPF
1/16 (1.5) 7/16 (11)
EBVCR
EBVCL
Figure 25
Step 11. Spillage Test and Safety Limit Switch OperationSpillage TestAfter appliance installation, perform this spillage test to verify that proper venting conditions exist:
4 | - Push the red reset button on the switch. |
5 | - Reinstall the switch/bracket assembly. |
6 | - Reinstall the side baffle. |
7 | - Reinstall front glass door. |
8 | - Raise the bottom hinged panel. |
The appliance should then relight and remain lit. If this does not occur, check unit for a blocked flue condition.
SAFETY SWITCH LOCATION (EBVCL SHOWN) EBVST and EBVPF Safety Switch Location Also as Shown;
EBVCR Location on the Left End of the Fireplace.
1- Place unit in its
2 - Close all doors and windows in the room. Turn on all exhaust fans in the house. 3 - Light the appliance.
4 - Wait 15 minutes.
5 - To check for venting action, start by holding a smoke producing device within an inch of one edge (side edge, not top or bottom edge) of one glass enclosure panel. The smoke should be drawn toward the edge of the glass enclosure panel. Continue the test by moving the smoke producing device along the entire length of both
6 - If the smoke is not drawn towards the edges of the glass door turn off the appli- ance and call a qualified service technican.
FIREBOX
SIDE WALL
BRACKET
SECURING SCREW
SAFETY SWITCH
Figure 26
FIREBOX SIDE BAFFLE SECURING SCREW
FIREBOX SIDE BAFFLE
SAFETY LIMIT SWITCH
TOP RADIANT PANEL
AND EYEBROW
CABINET
SIDE WALL
14
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.