Miele W 1986 operating instructions Plumbing connection, Water connection

Models: W 1986

1 52
Download 52 pages 40.04 Kb
Page 46
Image 46

Plumbing connection

Water connection

Connect the cold water intake hose (blue mark) to the cold water valve and the hot water intake hose (red mark) to the hot water valve.

If the machine is being connected to a cold water supply only, both the hot and cold water intake hoses must be attached to the cold water valve through the use of a Y adapter (avail- able at a hardware store). Both hoses must be connected to a water source, or the machine will not function prop- erly. Do not connect the washer to hot water only.

Turn on the valve(s) and check for leaks. The water pressure must be within 15-145 psi (1-10 bar). If the water pressure is greater that 145 psi

(10 bar), a pressure reducer must be installed. If the water pressure is below 15 psi (1 bar), there will not be enough water available for a complete fill.

The water intake hoses are equipped with screen filters. Please do not re- move these filters except for cleaning.

Tips for a hot water connection

The hot water temperature from the hot water valve must not exceed 60°C, the ideal temperature is 55°C.

If there is no water pressure at the hot water inlet, the unit automatically switches to cold water after several minutes.