154
Band Width: Ports 1 to 24 support by-port ingress and egress rate control. For
example, if port 1 is set to 10Mbps, you can set it’s effective egress rate to
1Mbps and ingress rate to 500Kbps. The MIL-SM2401M-STK will perform
flow control or backpressure to confine the ingress rate to meet the specified
rate.
In: Enter the port effective ingress rate. The valid range is 0 to 1000. The
unit is 100K.
0: disable rate control.
1 to 1000: valid rate value
Out: Enter the port effective egress rate. The valid range is 0 to 1000. The
unit is 100K.
0: disable rate control.
1 to 1000: valid rate value.
Priority: This static priority is based on each port setting. If the port priority is set
high, incoming frames from this port will always be high priority frames.
Security: A port in security mode will be “locked” unless address learning is
enabled. Only the incoming packets with SMAC already existing in the address
table can be forwarded normally. User can disable the port from learning any new
MAC addresses, and then use the static MAC addresses screen to define a list of
MAC addresses that can use the secure port.
Enter the settings, then click the Apply button to save the changes on this page.