Miller Electric 15A, 30A manual Replacing Diffuser, Troubleshooting

Models: 15A 30A

1 36
Download 36 pages 23.19 Kb
Page 24
Image 24

6-7. Replacing Diffuser

Turn Off welding power source. 1 Nozzle

2 FasTip

To remove, see Section 6-2.

3 Diffuser

Remove diffuser and replace.

3

2

1

 

Tools Needed:

 

3/8 in

 

Ref. 803 348-G

6-8. Troubleshooting

 

 

 

Trouble

Remedy

 

 

 

 

No weld output; gun/feeder does not

Secure weld control plug in 115 volts ac receptacle (see weld control Owner’s Manual).

work.

 

Place Power switch on welding power source in the On position (see welding power source Owner’s

 

 

Manual).

 

 

Erratic weld output.

Tighten and clean all connections.

 

 

Pressing gun/feeder trigger does not en-

Secure plug from gun/feeder trigger cord into 10-socket receptacle on weld control (see Sections 4-5and

ergize weld control; welding wire is not

4-6).

energized; shielding gas does not flow.

 

 

 

Wire feeds, shielding gas flows, but

Secure control cable leads in weld control (see weld control Owner’s Manual).

welding wire is not energized.

 

See Troubleshooting section in welding power source Owner’s Manual.

 

 

 

Wire feeds erratically.

Check and correct drive roll pressure (see Section 4-8).

 

 

 

Clean drive roll or replace drive roll (see Section 6-4).

 

 

 

Decrease spool brake pressure (see Section 4-8).

 

 

OM-1213 Page 20