Trouble

Remedy

 

 

Low power output at generator power ac

Check Amperage control setting.

receptacles.

 

 

 

 

Check engine speed, and adjust if necessary (see Section 8-4or 8-5). Output stops if engine speed is

 

too low.

 

 

 

Move throttle lever to 60 Hz position for 60 Hz equipment (see Section 6-1or 6-2).

 

 

Erratic power output at generator

Check fuel level.

power ac receptacles.

 

 

 

 

Check receptacle wiring and connections.

 

 

 

Check throttle/governor linkage for smooth, non-binding operation.

 

 

 

Service air cleaner according to engine manual.

 

 

 

Check engine speed, and adjust if necessary (see Section 8-4or 8-5). Output stops if engine speed is

 

too low.

 

 

 

Have Factory Authorized Service Agent check brushes, slip rings, resistor R3 (Kohler only), and

 

circuit board PC1.

 

 

C. Engine

Trouble

Remedy

 

 

Engine will not crank (electric-start

Reset ignition circuit breaker (see Section 8-3).

models only).

 

 

 

 

Check battery voltage.

 

 

 

Check battery connections and tighten if necessary.

 

 

 

Have Factory Authorized Service Agent check engine ignition circuit.

 

 

Engine will not start.

Check fuel level (see Section 5-4or 5-5).

 

 

 

Move choke lever to correct position (see Section 6-1or 6-2).

 

 

 

Open fuel valve (see Section 5-4or 5-5). Close fuel valve before moving unit or carburetor may flood and

 

make starting difficult.

 

 

 

Check battery voltage (electric-start models only).

 

 

 

Check battery connections and tighten if necessary (electric-start models only).

 

 

 

Check oil level (see Section 5-4or 5-5). Engine stops if oil level is too low. Refill crankcase with proper

 

viscosity oil for operating temperature.

 

 

 

Have Factory Authorized Service Agent check low oil level shutdown switch.

 

 

Engine stopped during normal

Check fuel level (see Section 5-4or 5-5).

operation.

 

 

 

 

Open fuel valve (see Section 5-4or 5-5). Close fuel valve before moving unit or carburetor may flood and

 

make starting difficult.

 

 

 

Check oil level (see Section 5-4or 5-5). Engine stops if oil level is too low.

 

 

 

Have Factory Authorized Service Agent check low oil level shutdown switch.

 

 

 

Check unit operating angle. Low oil level shutdown switch may stop engine if unit is tilted.

 

 

Battery discharges between uses (elec-

Clean battery, terminals, and posts with baking soda and water solution; rinse with clear water.

tric-start models only).

 

 

 

 

Periodically recharge battery (approximately every 3 months).

 

 

 

Replace battery.

 

 

 

Check voltage regulator and connections according to engine manual.

 

 

Unstable or sluggish engine speeds.

Check engine speed, and adjust if necessary (see Section 8-4or 8-5).

 

 

 

Check throttle/governor linkage for smooth, non-binding operation.

 

 

 

Tune-up engine according to engine manual.

 

 

Return To Table Of Contents

OM-499 Page 29

Page 33
Image 33
Miller Electric 6000 Engine, Circuit board PC1, Make starting difficult, Check battery voltage electric-start models only