Miller Electric 6000 manual Volt-Ampere Curves, Max Mid Min

Models: 6000

1 60
Download 60 pages 39.76 Kb
Page 17
Image 17

4-7. Volt-Ampere Curves

 

A.

60 Hz Model

 

 

 

 

 

 

 

 

 

 

80

 

 

 

 

 

 

 

 

 

 

 

 

70

 

 

 

 

 

 

 

 

 

 

 

 

60

 

 

 

 

 

 

 

 

 

 

 

VOLTS

50

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LOAD

40

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30

 

 

 

 

 

 

 

 

MAX

 

 

 

 

 

 

 

 

 

MID

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20

 

 

 

MIN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

 

 

 

 

 

 

 

 

 

 

 

 

0

0

25

50

75

100

125

150

175

200

225

250

 

 

 

 

 

 

 

 

 

LOAD AMPS

 

 

 

 

The volt-ampere curve shows the minimum and maximum voltage and amperage output capabilities of the welding generator. Curves of all other settings fall between the curves shown.

B. 50 Hz Model

LOAD VOLTS

80

 

 

 

 

 

 

 

 

 

 

70

 

 

 

 

 

 

 

 

 

 

60

 

 

 

 

 

 

 

 

 

 

50

 

 

 

 

 

 

 

 

 

 

40

 

 

 

 

 

 

 

 

 

 

30

 

 

 

 

 

 

 

MAX

 

 

 

 

 

 

 

 

MID

 

 

 

 

20

 

 

 

MIN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

 

 

 

 

 

 

 

 

 

 

0

 

 

 

 

 

 

 

 

 

 

0

25

50

75

100

125

150

175

200

225

250

LOAD AMPS

198 570

Return To Table Of Contents

OM-499 Page 13

Page 17
Image 17
Miller Electric 6000 manual Volt-Ampere Curves, Max Mid Min