SECTION 3 − DEFINITIONS
3-1. Symbol Definitions
| Engine Choke |
| Read Operator’s | A | Amperes | V | Volts |
|
| Manual | |||||
|
|
|
|
| |||
| Engine Oil |
| Fuel |
| Battery (Engine) |
| Engine |
| Positive |
| Negative |
| Alternating Current |
| Output |
|
|
| (AC) |
| |||
|
|
|
|
|
|
| |
h | Hours | s | Seconds |
| Time |
| Protective Earth |
|
| (Ground) | |||||
|
|
|
| ||||
|
|
|
|
|
|
|
Circuit Breaker
Temperature
SECTION 4 − SPECIFICATIONS
NOTE
This unit uses either a Kohler or a Honda engine. Differences between models are noted throughout this manual.
4-1. Weld, Power, And Engine Specifications
Welding | Weld Output | Rated | Maximum | Generator Power |
|
| |
Welding | Open Circuit | Fuel Capacity | Engine | ||||
Mode | Range | Rating | |||||
Output | Voltage |
|
| ||||
|
|
|
|
| |||
|
|
|
|
|
|
| |
|
|
|
|
|
| Kohler CS12STG | |
|
| 180 A, 25 V, |
|
|
| ||
|
|
|
|
| |||
|
| 30% Duty |
|
| |||
|
|
|
| ||||
|
| Cycle |
|
| |||
| 40 − 180 A | 80 | 6 kVA/kW (Peak) | Kohler: | 12 HP (360 CC), | ||
|
| ||||||
| 130 A, 25 V, | 5.5 kVA/kW | 1.8 gal (6.9 L) Tank | Gasoline Engine | |||
| (60 Hz) | (60 Hz) | |||||
CC/DC | 60% Duty | (Continuous) |
| OR | |||
40 − 160 A | 70 |
| |||||
| Cycle | 50/25 A, | Honda: | Honda GX390 | |||
| (50 Hz) | (50 Hz) | |||||
| 100 A, 25 V, | 110/220 V AC, 50 Hz | 1.7 gal (6.4 L) Tank | ||||
|
|
| |||||
|
|
| 120/240 V AC, 60 Hz |
| |||
|
| 100% Duty |
|
| |||
|
|
|
|
| |||
|
| Cycle |
|
|
| ||
|
|
|
|
| 13 HP (390 CC), | ||
|
|
|
|
|
| ||
|
|
|
|
|
| Gasoline Engine | |
|
|
|
|
|
|
|
Return To Table Of Contents |