Miller Electric Big Blue 600 X, Big Blue 500 PT manual Weld, Power, And Engine Specifications

Models: Big Blue 600 X Big Blue 500 PT

1 90
Download 90 pages 33.37 Kb
Page 19
Image 19

SECTION 4 − SPECIFICATIONS

4-1. Weld, Power, And Engine Specifications

 

 

 

Maximum

 

 

 

Welding

Weld Output

Rated Welding

Open-

Generator Power

Engine

Fuel

Mode

Range

Output

Circuit

Rating

Capacity

 

 

 

 

Voltage

 

 

 

 

 

 

 

 

 

 

 

65 − 600 A

 

 

Standard

 

 

 

 

95

Single-Phase,

 

 

 

(CC Models)

 

 

 

CC/DC

500 A, 40 Volts DC,

4 kVA/kW, 34/17 A,

 

 

 

 

Perkins

 

20 − 600 A

 

120/240 V AC,

 

 

100% Duty Cycle

 

 

 

(CC/CV Models)

 

50/60 Hz

 

 

 

550 A, 42 Volts DC,

 

Perkins 404C-22T

 

 

 

 

Three-Phase Generator

25 gal

 

 

60% Duty Cycle

 

Water-Cooled,

 

 

 

Option*

(95 L)

 

 

600 A,

 

Four-Cylinder,

CV/DC

 

 

Single-Phase/Three-Phase,

 

(CC/CV

 

30 Volts DC (CC),

 

12/20 kVA/kW, 50/48A,

47 HP Turbocharged

 

14 − 40 V

40% Duty Cycle

56

120/240 VAC, 60 Hz

Diesel Engine

 

Models

 

 

 

*In Addition To Standard

 

 

Only)

 

 

 

 

 

 

 

 

 

4 kVA/kW Generator Power

 

 

 

 

 

 

 

 

 

4-2. Dimensions, Weights, And Operating Angles

Dimensions

Height

60 in (1524 mm)

(to top of muffler)

 

 

 

 

28-1/2 in (724 mm)

Width

(mtg. brackets turned in)

30-3/4 in (781 mm)

 

 

(mtg. brackets turned out)

 

 

 

Depth

65-1/8 in

(1654 mm)

 

 

 

A

65-1/8 in

(1654 mm)

 

 

B*

56 in (1422 mm)

 

 

C*

46-1/2 in (1181)

 

 

 

D*

9-5/8 in

(244 mm)

E27-1/2 in (699 mm)

F1 in (25 mm)

G29-13/16 in (757 mm)

H9/16 in (14 mm) Dia.

4 Holes

*With mounting brackets in center position. Dimensions vary with location of mounting brackets.

 

Weight

 

 

w/ Perkins

No fuel: 1700 lb (771 kg)

404-22T

w/fuel: 1875 lb (850 kg)

 

 

Lifting Eye Weight Rating:

2500 lb (1134 kg) Maximum

A

B C

D

G

! Do not exceed tilt angles or engine could be damaged or unit could tip.

! Do not move or operate unit where it could tip.

 

 

30°

H

20°

30°

 

 

 

20°

 

F

E

802 161-A

OM-4429 Page 15

Page 19
Image 19
Miller Electric Big Blue 600 X manual Weld, Power, And Engine Specifications, Dimensions, Weights, And Operating Angles