Miller Electric Big Blue 500 PT manual Inspecting And Cleaning Optional Spark Arrestor Muffler

Models: Big Blue 600 X Big Blue 500 PT

1 90
Download 90 pages 33.37 Kb
Page 48
Image 48

9-4. Inspecting And Cleaning Optional Spark Arrestor Muffler

! Stop engine and let cool.

1 Spark Arrestor Muffler

 

2

Cleanout Plug

 

Remove plug and remove any dirt

 

covering cleanout hole.

 

Start engine and run at idle speed to

 

blow out cleanout hole. If nothing

 

blows out of hole, briefly cover end

 

of

exhaust pipe with fireproof

2

material.

! Stop engine and let cool.

Reinstall cleanout plug.

1

Tools Needed: 3/8 in

803 656 / Ref. 215 158

9-5. Checking Generator Brushes

! Stop engine and let cool.

1 Generator Brush

Remove brushes from brush holder.

Replace brushes if damaged or if brush material is at or near minimum length.

Minimum Length: 5/8 in (16 mm)

New Length: 1-1/4 in (32 mm)

Replace

 

Damaged Brushes

1

 

Ref. 215 664

OM-4429 Page 44

Page 48
Image 48
Miller Electric Big Blue 500 PT manual Inspecting And Cleaning Optional Spark Arrestor Muffler, Checking Generator Brushes