6-8. Troubleshooting
A. Welding
Trouble | Remedy |
|
|
No weld output. | Check control settings. |
|
|
| Check weld connections. |
|
|
| Check fuse F1 and replace if open (see Section |
|
|
| Be sure all equipment is disconnected from receptacles when starting unit. |
|
|
| Have Factory Authorized Service Agent check brushes, slip rings, and integrated rectifier SR2. |
|
|
| Check plug PLG6 connection. |
|
|
Low weld output. | Check fuse F1 and replace if open (see Section |
|
|
| Check control settings. |
|
|
| Check and adjust engine speed (see Section |
|
|
| Service air cleaner according to engine manual. |
|
|
| Have Factory Authorized Service Agent check brushes and slip rings. |
|
|
High weld output. | Check control settings. |
|
|
| Check and adjust engine speed (see Section |
|
|
Erratic weld output. | Check control settings. |
|
|
| Tighten and clean connections to electrode and workpiece. |
|
|
| Use dry, |
|
|
| Remove excessive coils from weld cables. |
|
|
| Tighten and clean connections both inside and outside welding generator. |
|
|
| Check and adjust engine speed (see Section |
|
|
| Have Factory Authorized Service Agent check brushes and slip rings. |
|
|
B. Auxiliary Power
Trouble | Remedy |
|
|
No output at auxiliary power recep- | Reset circuit breakers (see Sections |
tacles. |
|
|
|
| Press receptacle Reset button (see Section |
|
|
| Check fuse F1 and replace if open (see Section |
|
|
| Check plug PLG6 connection. |
|
|
| Have Factory Authorized Service Agent check brushes, slip rings, and integrated rectifier SR2. |
|
|
High power output. | Check and adjust engine speed (see Section |
|
|
Low power output. | Check fuse F1 and replace if open (see Section |
|
|
| Increase Fine Adjust control R1 setting. |
|
|
Erratic power output. | Check fuel level. |
|
|
| Check and adjust engine speed (see Section |
|
|
| Check receptacle wiring and connections. |
|
|