SECTION 5 – OPERATING AUXILIARY EQUIPMENT

5-1. Standard Receptacles

Ref. ST-178 079-A

Auxiliary power decreases as

weld current increases.

Set Fine Adjust control R1 at

10

for full auxiliary power
.
1
120 V 15 A AC Receptacles
GFCI-2 And GFCI-3
GFCI-2 and GFCI-3 supply 60 Hz
single-phase
power at
weld/power
speed.
Maximum
output from each
receptacle is 2.4 kVA/kW (CSA:
1.8 kVA/kW).
If
a ground fault is detected,
Reset
button pops out and the circuit
opens to disconnect the faulty
equipment. Check for faulty tools,
cords,
etc. connected
to the recep
-
tacle.
Press reset
button to resume
operation.

At

least
once a month, run en

-

gine

at weld/power speed and

press Test button to verify

GFCI

is working properly
.
2
240 V 50 A AC Receptacle
RC1
RC1 supplies 60 Hz single-phase
power
at weld/power speed. Maxi
-
mum
output is 8 kV
A/kW.
3 Circuit Breakers CB1 And
CB2
CB1 and CB2 protect RC1 from
overload. If CB1 or CB2 opens,
RC1
and one of the 120 volt
recep
-
tacles does not work. 120 volts
may
still be present at RC1.
4 Circuit Breakers CB3 And
CB4
CB3 and CB4 protect GFCI-2 and
GFCI-3 from overload. If CB3 or
CB4 opens, the receptacle does
not work.

If

a circuit breaker continues to

open, contact a Factory Au-

thorized

Service Agent.
Total output of receptacles limited
to 8 kVA/kW. Example: If 20 A is
drawn from GFCI-2 and GFCI-3,
only
13 A is available at RC1:
2
x (120 V x 20
A) + (240 V x 13 A)
=
7.9 kV
A/kW