Miller Electric EXTREME 360 manual Remote 14 Receptacle Information, Socket Information

Models: EXTREME 360

1 40
Download 40 pages 16.87 Kb
Page 22
Image 22

4-7.

 

Remote 14 Receptacle Information

 

 

 

 

 

 

 

Socket*

Socket Information

 

 

 

 

24 VOLTS AC

A

24 volts ac. Protected by circuit breaker CB2.

 

 

 

 

 

 

A

 

J

 

B

Contact closure to A completes 24 volts ac

K

 

 

contactor control circuit.

B

 

I

 

 

 

 

 

 

 

I

115 volts ac. Protected by circuit breaker CB1.

C

L N

H

115 VOLTS AC

 

 

D

 

M

G

 

J

Contact closure to I completes 115 volts ac

 

 

E

F

 

 

contactor control circuit.

 

 

 

 

 

C

Output to remote control; 0 to +10 volts dc, +10

 

 

 

 

 

 

volts dc in MIG mode.

 

 

 

 

REMOTE

D

Remote control circuit common.

 

 

 

 

OUTPUT

E

0 to +10 volts dc input command signal from

 

 

 

 

CONTROL

 

 

 

 

 

 

remote control.

 

 

 

 

 

M

CC/CV select

 

 

 

 

A/V

F

Current feedback; +1 volt dc per 100 amperes.

 

 

 

 

 

 

 

 

 

 

AMPERAGE

H

Voltage feedback; +1 volt dc per 10 output recep-

 

 

 

 

VOLTAGE

 

tacle volts.

 

 

 

 

 

G

Circuit common for 24 and 115 volts ac circuits.

 

 

 

 

GND

K

Chassis common.

 

 

 

 

 

*The remaining sockets are not used.

4-8. Optional 115 Volts AC Duplex Receptacle And Circuit Breakers

1 115 V 10 Amp AC Receptacle

Power is shared between duplex receptacle and Remote 14 recep- tacle (see Section 4-7).

1

2 Circuit Breaker CB1

3 Circuit Breaker CB2

CB1 protects duplex receptacle and 115 volts ac portion of Remote 14 receptacle from overload.

CB2 protects 24 volts ac portion of Remote 14 receptacle from overload.

Press button to reset breaker.

2 3

803 691-C

OM-229 409 Page 18