5-2. Adjusting Spark Gaps

 

 

 

 

 

 

 

Turn Off unit and welding power

 

 

 

source and disconnect input power.

 

 

Rear Of Unit

Loosen screw on spark gap access

 

 

 

 

 

 

door and open.

 

 

 

1 Tungsten End Of Point

 

 

 

Do not clean or dress tungsten.

 

 

 

Replace point if tungsten end

 

 

 

disappears.

 

 

 

2

Spark Gap

 

 

 

Normal spark gap is 0.008 in (0.203

 

 

 

mm).

 

 

 

If spark gaps are okay, reinstall

 

 

 

door. If adjustment is needed, con-

 

 

 

tinue as follows:

 

 

 

3

Adjustment Screws

 

 

 

Loosen screws. Place gauge of

 

 

 

proper thickness in spark gap.

 

 

 

4

Pressure Point

 

 

 

Apply slight pressure at point until

 

 

 

gauge is held firmly in gap. Tighten

 

 

 

adjustment screws to 12 in/lbs

 

 

 

torque (overtightening will deform

 

 

 

plastic base). Repeat gauge adjust-

 

 

 

ment with other gap.

1

2

 

Close access door.

 

 

 

 

 

 

 

3

4

 

 

 

Tools Needed:

 

 

 

 

5/32 in

0.008 in

 

 

 

(0.203 mm)

 

 

 

 

 

 

 

Ref. 098 956-G