3-5. FIELD INSTALLATION OF PULSER

WARNING: ELECTRIC SHOCK can kill.

Do not touch live electrical parts.

Shut down welding power source, and dis- connect input power employing lockout/tagging procedure before beginning this installation.

Lockout/tagging procedures consist of pad- locking line disconnect switch in open position, removing fuses from fuse box, or shutting off and red-tagging circuit breaker or other discon- necting device.

1.Remove top cover from TIG-Unit, if applicable.

2.Remove right blank panel from front of TIG-Unit. Save screws; discard blank panel.

3.Examine inside of TIG-Unit behind front panel for lo- cation of lead harnesses, etc.

4.Carefully slide Pulser unit into opening on front pan- el of TIG-Unit. Secure Pulser with the four screws removed from blank panel in Step 2.

5.Route leads from Pulser down top of center mount- ing panel and then to right of terminal strip 1T. (The terminal strip is located on top of center mounting panel toward rear of TIG-Unit; the terminals are la- beled directly below the strip; see Figure 3-2.)

6.Remove jumper link 4 (across terminals 84 and 83) on terminal strip 1T. See Circuit Diagram 7-1.

7.Connect Pulser leads to correspondingly numbered terminals (41, 42, 43, 84, 83, 72) on terminal strip 1T. The leads from Pulser are all numbered.

8.Connect grey lead 42 from rear of Pulser case to front center mounting panel where existing grey lead 42 is connected to chassis (not to terminal strip).

9.Secure leads to existing harness with nylon cable ties or tape to maintain a proper lead dress.

10.Reinstall cover onto TIG-Unit, if applicable.

3-6. FIELD INSTALLATION OF ELECTROSLOPE

WARNING: ELECTRIC SHOCK can kill.

Do not touch live electrical parts.

Shut down welding power source, and dis- connect input power employing lockout/tagging procedure before beginning this installation.

Lockout/tagging procedures consist of pad- locking line disconnect switch in open position, removing fuses from fuse box, or shutting off and red-tagging circuit breaker or other discon- necting device.

1.Remove top cover from TIG-Unit, if applicable.

2.Remove left blank panel from front of TIG-Unit. Save screws; discard blank panel.

3.Examine inside of TIG-Unit behind front panel for lo- cation of lead harnesses, etc.

4.Carefully slide Electroslope unit into opening on front panel of TIG-Unit. Secure Electroslope with the four screws removed from blank panel in Step 2.

5.Route leads from Electroslope down top of center mounting panel and then to right of terminal strip 1T. (The terminal strip is located on top of center mount- ing panel toward rear of TIG-Unit; the terminals are labeled directly below the strip; see Figure 3-2.)

6.Connect grey lead 42 from rear of Electroslope case to front center mounting panel where existing grey lead 42 is connected to chassis (not to terminal strip).

7.Remove jumper links 1 (across terminals 3 and 2), 2 (across terminals 71 and 70), and 3 (across termi- nals 76 and 78) on terminal strip 1T. See Circuit Dia- gram 7-1.

8.For Models Effective With Serial No. HK261770: Connect Electroslope leads to correspondingly numbered terminals (3, 2, 5, 6, 7, 41, *42, 43, 71, 70, 56, 61, *42, 62, 76, 78, 72, 58, 59) on terminal strip 1T. Connect Electroslope leads 30 and 37 to corresponding terminal on terminal strip 2T. The leads from Electroslope are all numbered. Connect lead 60 from Electroslope to terminal 1 on relay CR2 (see Figure 3-2).

*Connect only one lead 42 to each 42 terminal. The leads are cut to proper length and will only reach the appropriate segment of the terminal strip.

9.For Models Prior To Serial No. HK261770: Connect Electroslope leads to correspondingly numbered terminals (3, 2, 5, 6, 7, 41, *42, 43, 71, 70, 56, 61, *42, 62, 76, 78, 72) on terminal strip 1T. Connect Electroslope lead 60 to terminal 1 on relay CR2.

If The Unit DOES NOT Have Preflow:

c.Replace existing connector on Electroslope lead 59 with a 3/16 in. female friction connector, and connect lead 59 to terminal 4 on relay CR2.

d.Individually tape and tie remaining Electroslope leads 30, 37, and 58 to existing wiring harness.

If The Unit DOES Have Preflow:

a.Replace existing connectors on Electroslope leads 30 and 37 with a 1/4 in. piggyback (dual friction) connector.

b.Disconnect leads 30 and 37 from Preflow switch S200.

c.Reconnect lead 30 (from Step b) to piggyback connector on Electroslope lead 30, and recon- nect lead 37 (from Step b) to piggyback connec- tor on Electroslope lead 37.

d.Install piggyback connector on Electroslope lead 30 onto terminal of Preflow switch from which lead 30 (from Step b) was removed.

e.Install piggyback connector on Electroslope lead 37 onto terminal of Preflow switch from which lead 37 (from Step b) was removed.

OM-530 Page 6

Page 10
Image 10
Miller Electric KC237900 manual Field Installation of Pulser, Field Installation of Electroslope

KC237900 specifications

The Miller Electric KC237900 is a standout model in the realm of welding technology, specifically designed for versatility and efficiency. This machine embodies Miller's commitment to innovation and quality, making it a popular choice among professionals and hobbyists alike.

One of the main features of the KC237900 is its advanced inverter technology, which allows the unit to operate efficiently across a range of welding applications. This technology ensures that the welder maintains a stable arc for precision welding, even on thin materials. The inverter design also contributes to a lighter and more compact machine, enhancing portability without compromising on power.

The KC237900 supports multiple welding processes, including MIG, Flux-Cored, and Stick welding. This versatility makes it suitable for a variety of projects, from automotive repairs to intricate fabrication tasks. The machine’s ability to handle diverse materials, including steel, stainless steel, and aluminum, further expands its application scope.

Another characteristic of the Miller Electric KC237900 is its user-friendly interface. The digital display provides clear information on amperage and voltage settings, allowing welders to make quick adjustments as needed. Additionally, the intuitive control panel simplifies the operation, making it accessible to users with varying skill levels.

The arc technology integrated into the KC237900 contributes to its smooth and stable welding performance. The unit utilizes Miller's Auto-Set feature, which automatically adjusts parameters based on material thickness and type. This feature not only speeds up the setup process but also enhances the overall weld quality.

Durability is another key aspect of the KC237900. Built with robust materials, the machine is designed to withstand the rigors of job site conditions. Its protective features, such as thermal overload protection, ensure that the unit operates safely and efficiently.

In conclusion, the Miller Electric KC237900 is a high-performance welding machine that combines advanced inverter technology, versatility, and user-friendly features. With its ability to handle multiple welding processes and materials, along with its focus on reliability and ease of use, it stands out as an excellent choice for both experienced welders and newcomers to the trade. Whether for professional use or personal projects, the KC237900 delivers the performance and quality that Miller Electric is known for.