5-2. Activating The Dry Charge Battery (If Applicable)

3

2

1

4

5 A For 30 Minutes

OR+

Tools Needed:

30 A For 12 Minutes

 

5-3. Connecting The Battery

Y Connect (−) Cable Last.

+

YAlways wear a face shield, rubber gloves and protective clothing when working on a battery.

Remove battery from unit.

4Vent Caps

5Sulfuric Acid Electrolyte (1.265 Specific Gravity)

6Well

Fill each cell with electrolyte to bottom of well (maximum).

YDo not overfill battery cells.

Wait ten minutes and check electro- lyte level. If necessary, add electro- lyte to raise to proper level. Reins- tall vent caps.

7 Battery Charger

YRead and follow all instruc- tions supplied with battery charger.

Charge battery for 12 minutes at 30 amperes or 30 minutes at 5 am- peres. Disconnect charging cables and install battery.

.When electrolyte is low, add

only distilled water to cells to maintain proper level.

drybatt1 6/05 − S-0886

190 377

OM-494 Page 15

Page 19
Image 19
Miller Electric Miller DU-OP manual Activating The Dry Charge Battery If Applicable, Connecting The Battery, For 30 Minutes