Miller Electric R-115 manual White Lead

Models: R-115

1 36
Download 36 pages 16.19 Kb
Page 22
Image 22

3-17. Connection For Welding Power Sources With Hubbell Receptacles

A B C 1

D

3

E

2

.Make ground lead connections

according to Section 3-9before following this procedure.

1Terminal Block 1T

2Interconnecting Power Cord

3Green Lead (Connected To Ground In Section 3-9)

Connect remaining leads to terminal block as follows:

A:115 VAC/Neutral Lead

B:115 VAC/Hot Lead

C:No Connection

D:No Connection

E:115 VAC/Contact Closure Lead

Secure strain relief clamp around cord.

Reinstall and secure wrapper to unit.

Connect remaining end of cord to welding power source.

Tools Needed:

1/4 in

Ref. 802 310 / Ref. 193 749

3-18. Connection For Miller Welding Power Sources With 14-Socket Receptacle

 

 

 

 

 

 

 

1

Terminal Block 1T

 

 

 

 

 

 

. Make ground lead connections

 

2

Interconnecting Power Cord

 

 

 

 

 

 

3

White Lead

 

 

 

 

 

 

according to Section 3-9before

 

4

Black Lead

 

 

 

 

 

 

following this procedure.

 

 

 

 

 

 

 

 

 

 

5

Red Lead

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6 Green Lead (Connected To

 

 

 

 

 

 

 

 

 

Ground In Section 3-9)

 

 

 

 

 

6

 

 

Connect

remaining

leads

to

 

 

 

E

 

 

terminal block as follows:

 

 

 

D

5

 

 

A: White Lead (115 VAC/Neutral)

 

C

 

 

 

B

 

 

 

B: Black Lead (115 VAC/Hot)

 

A

 

 

 

 

 

 

C: No Connection

 

 

 

 

 

 

 

 

 

 

 

1

 

 

 

B A K

J I

D: No Connection

 

 

 

 

 

 

C

L N

H

E: Red Lead (115 VAC/Contact

 

3

 

 

Closure)

 

 

 

 

 

 

4

D M

G

Secure strain relief clamp around

 

 

 

 

E

F

 

 

 

 

 

cord.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

Reinstall and secure wrapper to

 

 

 

 

 

 

 

unit.

 

 

 

 

 

 

 

 

 

 

Connect remaining end of cord to

 

 

 

 

 

 

 

welding power source.

 

 

Tools Needed:

 

 

 

 

 

 

 

 

 

 

 

 

1/4 in

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ref. 802 310 / Ref. 193 749

OM-193 471 Page 18

 

 

 

 

 

 

 

 

 

Page 22
Image 22
Miller Electric R-115 manual White Lead