Miller Electric R-115 manual To Terminal E Lead, For Welding power sources

Models: R-115

1 36
Download 36 pages 16.19 Kb
Page 20
Image 20

3-13. Connection For Hobart Welding Power Sources With 5-Socket And 115 Volt AC Receptacles

 

 

 

 

. Make ground lead connections

 

 

 

 

 

according to Section 3-9before

 

 

 

 

 

following this procedure.

 

 

 

 

 

1

 

 

 

 

E

 

 

A

B

C

D

3

 

 

 

 

 

 

E

 

 

 

 

D

A

 

 

 

 

C

B

4

 

 

 

 

 

 

 

 

 

2

 

Tools Needed:

 

 

 

 

 

 

1/4 in

 

 

1Terminal Block 1T

23-Conductor Cord

32-Conductor Cord

4Green Lead (Connected To Ground In Section 3-9)

Connect remaining leads to terminal block as follows:

A:115 VAC/Neutral Lead

B:115 VAC/Hot Lead

C:No Connection

D:Dry Contact Closure w/Respect To Terminal E Lead

E:115 VAC/Contact Closure Lead

.For welding power sources

requiring dry contact closure, move lead 38 at terminal block to terminal D.

Secure strain relief clamp around cords.

Reinstall and secure wrapper to unit.

Connect remaining cord ends to welding power source.

Ref. 802 310 / Ref. 193 749

3-14. Connection For Lincoln Welding Power Sources With 14-Socket Receptacle

 

. Make ground lead connections

 

1

Terminal Block 1T

 

 

 

 

2

Interconnecting Power Cord

 

 

according to Section 3-9before

 

 

 

 

3 Green Lead (Connected To

 

 

following this procedure.

 

 

 

 

 

 

 

 

 

Ground In Section 3-9)

 

 

 

 

 

 

 

 

 

 

 

 

 

Connect

remaining

leads

to

 

 

 

 

 

terminal block as follows:

 

 

 

 

 

 

A: 115 VAC/Neutral Lead

 

 

3

 

 

 

B: 115 VAC/Hot Lead

 

 

 

 

 

 

C: No Connection

 

 

 

E

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C

D

 

 

 

D: Dry Contact Closure w/Respect

 

 

 

 

 

To Terminal E Lead

 

 

B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A

 

 

 

 

E: 115 VAC/Contact Closure Lead

1

 

 

H

 

. For

welding power sources

 

F

G

I

J

requiring dry contact closure,

 

M

N

K

move lead 38 at terminal block

 

 

 

 

 

E

L

A

to terminal D.

 

 

 

 

D

C

B

Secure strain relief clamp around

 

 

 

 

 

cord.

 

 

 

 

2

 

 

 

Reinstall and secure wrapper to

 

 

 

 

 

unit.

 

 

 

 

 

 

 

 

Connect remaining end of cord to

Tools Needed:

 

 

 

 

welding power source.

 

 

 

 

 

 

 

 

 

 

 

 

1/4 in

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ref. 802 310 / Ref. 193 749

OM-193 471 Page 16

 

 

 

 

 

 

 

 

Page 20
Image 20
Miller Electric R-115 manual To Terminal E Lead, For Welding power sources