3-15. Connection For Lincoln Welding Power Sources With Terminal Strip Connections

 

 

. Make ground lead connections

 

 

according to Section 3-9before

 

 

following this procedure.

 

 

3

 

C D

E

A

B

 

1

 

 

 

 

2

 

 

GND

Tools Needed:

2 (Red)

 

 

4 (Orange)

 

 

31 (White)

 

 

32 (Black)

 

 

1/4 in

1Terminal Block 1T

2Interconnecting Power Cord

3Green Lead (Connected To Ground In Section 3-9)

Connect remaining leads to terminal block as follows:

A:115 VAC/Neutral Lead

B:115 VAC/Hot Lead

C:No Connection

D:Dry Contact Closure w/Respect To Terminal E Lead

E:115 VAC/Contact Closure Lead

.For welding power sources

requiring dry contact closure, move lead 38 at terminal block to terminal D.

Secure strain relief clamp around cord.

Reinstall and secure wrapper to unit.

Connect remaining end of cord to welding power source.

Ref. 802 310 / Ref. 193 749

3-16. Connection For AIRCO Welding Power Sources With Two-Prong Twistlock And 115 Volts AC Receptacles

 

 

3

 

C

D E

A B

 

 

 

1

 

 

 

 

2

Tools Needed:

 

 

1/4 in

.Make ground lead connections

according to Section 3-9before following this procedure.

1Terminal Block 1T

2Interconnecting Power Cord

3Green Lead (Connected To Ground In Section 3-9)

Connect remaining leads to terminal block as follows:

A:115 VAC/Neutral Lead

B:115 VAC/Hot Lead

C:No Connection

D:No Connection

E:115 VAC/Contact Closure Lead

Secure strain relief clamp around cord.

Reinstall and secure wrapper to unit.

Connect remaining end of cord to welding power source.

Ref. 802 310 / Ref. 193 749

OM-193 471 Page 17

Page 21
Image 21
Miller Electric R-115 manual Tools Needed Red, White, Black