Miller Electric R-115 manual Make ground lead connections, According to -9before

Models: R-115

1 36
Download 36 pages 16.19 Kb
Page 19
Image 19

3-11. Connection For Hobart Welding Power Sources With 19-Socket Receptacle

 

 

. Make ground lead connections

 

 

according to Section 3-9before

 

 

following this procedure.

 

 

3

 

C

D E

A

B

 

1

 

L M A

 

K U N B

 

 

J T V P C

 

 

H S R D

 

 

G F E

 

 

2

Tools Needed:

 

 

 

1/4 in

1Terminal Block 1T

2Interconnecting Power Cord

3Green Lead (Connected To Ground In Section 3-9)

Connect remaining leads to terminal block as follows:

A:115 VAC/Neutral Lead

B:115 VAC/Hot Lead

C:No Connection

D:Dry Contact Closure w/Respect To Terminal E Lead

E:115 VAC/Contact Closure Lead

.For welding power sources

requiring dry contact closure, move lead 38 at terminal block to terminal D.

Secure strain relief clamp around cord.

Reinstall and secure wrapper to unit.

Connect remaining end of cord to welding power source.

Ref. 802 310 / Ref. 193 749

3-12. Connection For L-TEC Welding Power Sources With 19-Socket Receptacle

A

1

B C

. Make ground lead connections according to Section 3-9before following this procedure.

3

D E

L M A

K U N B

J T V P C

H S R D

G F E

2

1Terminal Block 1T

2Interconnecting Power Cord

3Green Lead (Connected To Ground In Section 3-9)

Connect remaining leads to terminal block as follows:

A:115 VAC/Neutral Lead

B:115 VAC/Hot Lead

C:No Connection

D:No Connection

E:115 VAC/Contact Closure Lead

Secure strain relief clamp around cord.

Reinstall and secure wrapper to unit.

Connect remaining end of cord to welding power source.

Tools Needed:

1/4 in

Ref. 802 310 / Ref. 193 749

OM-193 471 Page 15

Page 19
Image 19
Miller Electric R-115 manual Make ground lead connections, According to -9before