General Terms: | 
  | 
Sequence | Selecting Sequence will allow setting of preflow, start, crater, and postflow times and parameters.  | 
Preflow  | Setting a time value for gas flow prior to arc start.  | 
Start | Provides voltage/arc adjust, wire feed rate, and time value for modified arc starts (which is only  | 
  | adjustable with the optional PDA with File Management/WaveWriter software).  | 
Crater  | Allows setting of voltage/arc adjust, wire feed rate, and time value for arc ends.  | 
Postflow  | Setting a time value for gas flow after arc end.  | 
Feeder Set Up  | Allow selection of Sequence and trigger functions.  | 
Auto Thread | Method of jogging wire without holding jog or trigger switch. Pressing Jog and Retract simultaneously  | 
  | will automatically feed wire. Default setting is 192 at a feed rate of 700 ipm (these values can be  | 
  | changed using a PDA with File Management/WaveWriter software). Pressing jog, purge, or trigger  | 
  | switch will terminate the   | 
5-2.  Power Switch
1 Power Switch
1
803