Miller Electric Remote Operator Interface manual Indicates a trigger, Closed error

Models: Remote Operator Interface

1 40
Download 40 pages 1.67 Kb
Page 30
Image 30

7-2. Diagnostics (Continued)

WELD

WAIT

Indicates a weld cycle wait error.

MOTR

COM

Indicates a motor communication error.

PLS

WAIT

Indicates a UIM communication error.

OVER

CRNT

Indicates an overcurrent error.

LOW

WFS

Indicates a low WFS command error.

E

STOP

Indicates an emergency stop error.

RMD

DONE

Indicates an arc error.

 

OVER

 

 

REL

 

 

 

 

 

 

 

 

 

 

 

 

 

AVER

 

 

TRIG

 

 

 

 

 

 

Indicates an over

Indicates a trigger

average current error.

closed error.

ERR

UNKN

Indicates an unknown error.

WELD WAIT

The weld wait error indicates unit was not ready for a weld sequence. Press Jog/ Purge button to clear error.

MOTR COM

The motor communication error indi- cates motor board lost data communica- tions. Press Jog/Purge button to clear error.

PLS WAIT

The uim communication error indicates user interface board lost data communications. Press Jog/Purge button to clear error.

OVER CRNT

The over current error indicates welding power source primary current is too high. Check and correct input power. Press Jog/ Purge button to clear error.

LOW WFS

The low wire feed speed error indicates actual wire feed speed is lower than wire feed speed command. Check for obstructions in the wire feed system or a faulty wire drive system. Press Jog/Purge button to clear error.

E STOP

The emergency stop error occurs if the user presses an emergency stop button. Reset the emergency stop button and press Jog/Purge button to clear error.

RMD DONE

The RMD done error indicates the RMD demo is completed. Press Jog/Purge button to clear error.

OVER AVER

The over average error indicates that cur- rent is outside the average range for the set program parameters. Check and correct program parameters. Press Jog/Purge but- ton to clear error.

REL TRIG

The release trigger error indicates the user held the trigger when starting a weld program Press Jog/Purge button to clear error.

ERR UNKN

The unknown error indicates a malfunc- tion in the system somewhere. Press Jog/ Purge button to clear error.

OM-217 834 Page 26

Page 30
Image 30
Miller Electric Remote Operator Interface manual Indicates a trigger, Closed error