SECTION 4 − INSTALLATION

.This manual contains information on CC and CC/CV units. Differences between models are noted throughout this manual.

4-1. Specifications

Input

Rated Welding

Amperage

Voltage

Maximum

Amperes Input At Rated Load

 

 

Open-

Output 50 Hz, Three-Phase

 

 

Power

Output

Range

Range

Circuit

 

 

 

 

 

 

 

 

Voltage DC

380 V

400 V

KVA

KW

 

 

 

 

 

 

 

 

 

Three

450 A @ 38 Volts DC,

 

 

 

 

 

 

 

100% Duty Cycle;

5 − 600

10 − 38

95

33

31

21.6

19.4

Phase

550 A @ 42 Volts DC,

 

 

 

 

 

 

 

 

60% Duty Cycle

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4-2. Duty Cycle And Overheating

Duty Cycle is percentage of 10 min- utes that unit can weld at rated load without overheating.

If unit overheats, thermostat(s) opens, output stops, and cooling fan runs. Wait fifteen minutes for unit to cool. Reduce amperage or duty cycle before welding.

NOTICE − Exceeding duty cycle can damage unit and void warranty.

100% Duty Cycle At 450 Amperes

60% Duty Cycle At 565 Amperes

Continuous Welding

6 Minutes Welding

4 Minutes Resting

Overheating

 

 

 

0

A/V

 

15

 

 

 

OR

 

Minutes

Reduce Duty Cycle

 

 

duty1 4/95 − SA-181 560

OM-203 034 Page 15

Page 19
Image 19
Miller Electric XMT 456 CC, XMT 456CV manual Specifications, Duty Cycle And Overheating