6-3. Removing Case and Measuring Input Capacitor Voltage
! Significant DC voltage can remain on capac- itors after unit is Off. Always check the volt- age as shown to be sure the input capacitors have discharged before working on unit.
1
1
Turn Off welding power source, and disconnect input power.
1 Outside Handle Screws
To loosen top, remove two outside handle screws from both handles and all side bolts.
2Interconnecting Board PC2
3Voltmeter
Measure the dc voltage across the screw terminals on RC3 and RC5 as shown until voltage drops to near 0 (zero) volts.
Proceed with job inside unit. Rein- stall cover when finished.
2
3
+ lead to lower right terminal, − lead to upper right terminal
Tools Needed:
5/16 in
802 260 / 801 536