Storage

The generator should be started at least once every seven days and allowed to run at least 30 minutes. If this cannot be done and you must store the unit for more than 30 days, use the following guidelines to prepare it for storage.

Generator Storage

Clean the generator as outlined in Cleaning.

Check that cooling air slots and openings on generator are open and unobstructed.

Long Term Storage Instructions

Fuel can become stale when stored over 30 days. Stale fuel causes acid and gum deposits to form in the fuel system or on essential carburetor parts. To keep fuel fresh, use Briggs

&Stratton FRESH START™ fuel stabilizer, available as a liquid additive or a drip concentrate cartridge.

There is no need to drain gasoline from the engine if a fuel stabilizer is added according to instructions. Run the engine for 2 minutes to circulate the stabilizer throughout the fuel system. The engine and fuel can then be stored up to 24 months.

If gasoline in the engine has not been treated with a fuel stabilizer, it must be drained into an approved container. Run the engine until it stops from lack of fuel. The use of a fuel stabilizer in the storage container is recommended to maintain freshness.

warning

Fuel and its vapors are extremely flammable and explosive.

Fire or explosion can cause severe burns or death.

WHEN STORING FUEL OR EQUIPMENT WITH FUEL IN TANK

Store away from furnaces, stoves, water heaters, clothes dryers, or other appliances that have pilot light or other ignition source because they can ignite fuel vapors.

WHEN DRAINING FUEL

Turn generator OFF and let it cool at least 2 minutes before removing fuel cap. Loosen cap slowly to relieve pressure in tank.

Drain fuel tank outdoors.

Keep fuel away from sparks, open flames, pilot lights, heat, and other ignition sources.

DO NOT light a cigarette or smoke.

Storing the Engine

See the engine operator’s manual for instructions on how to properly prepare the engine for storage.

Other Storage Tips

1.DO NOT store fuel from one season to another unless it has been treated as described in Long Term Storage Instructions.

2.Replace fuel container if it starts to rust. Rust and/or dirt in fuel can cause problems if it’s used with this unit.

3.Cover unit with a suitable protective cover that does not retain moisture.

warning

Storage covers can be flammable.

DO NOT place a storage cover over a hot generator.

Let equipment cool for a sufficient time before placing the cover on the equipment.

4.Store generator in clean, dry area.

17

Page 17
Image 17
Milwaukee 4960-24, 4970-24 Generator Storage, Long Term Storage Instructions, Storing the Engine, Other Storage Tips

4960-24, 4970-24 specifications

The Milwaukee 4960-24 and 4970-24 are powerful tools from Milwaukee's renowned lineup, specifically designed to meet the demands of professional tradespeople and DIY enthusiasts alike. These models are standout products in the company's commitment to durability, innovation, and user-friendly features that make them indispensable on the job site and in home improvement projects.

One of the main features of the Milwaukee 4960-24 and 4970-24 is their robust motor design. Both models are equipped with high-performance brushless motors that provide extended runtime and more efficient operation. This advanced motor technology not only ensures durability but also enhances the overall power output, allowing users to tackle even the toughest tasks with confidence.

The Milwaukee 4960-24 focuses on versatility, featuring a compact and lightweight design that makes it easy to maneuver in tight spaces. With an adjustable speed setting, it can accommodate a wide range of applications, from heavy-duty cutting to more delicate precision work. The ergonomically designed handle provides comfort during extended use, reducing fatigue and promoting productivity.

In contrast, the Milwaukee 4970-24 offers an augmented level of performance suited for more demanding applications. With a higher horsepower rating and enhanced torque, this model is ideal for heavy-duty cutting, grinding, and sanding tasks. Its rugged construction is built to withstand the rigors of job site conditions, featuring reinforced housings and robust components designed for long-lasting performance.

Both models boast advanced battery technologies, compatible with Milwaukee's M18 battery system. This compatibility allows users to interchange batteries across a wide selection of Milwaukee tools, improving efficiency and reducing downtime. Additionally, the intelligent battery management system optimizes performance, ensuring that users get the most out of their tools without the frustration of sudden power loss.

Incorporating user-friendly features, such as tool-free blade changes and integrated LED work lights, the Milwaukee 4960-24 and 4970-24 prioritize ease of use. These tools help enhance visibility in dimly lit workspaces and provide quick adjustments, catering to the needs of professionals who require flexibility and efficiency on the job.

In summary, the Milwaukee 4960-24 and 4970-24 are exceptional tools that embody the brand's dedication to quality, performance, and innovation. With their advanced motor technology, robust design, and thoughtful user features, these models exemplify what modern power tools should offer, making them valuable assets for users in various trades and applications.