System Ground

The generator has a system ground that connects the generator frame components to the ground terminals on the AC output receptacles. The system ground is connected to the AC neutral wire (the neutral is bonded to the generator frame).

Special Requirements

There may be Federal or State Occupational Safety and Health Administration (OSHA) regulations, local codes, or ordinances that apply to the intended use of the generator. Please consult a qualified electrician, electrical inspector, or the local agency having jurisdiction:

In some areas, generators are required to be registered with local utility companies.

If the generator is used at a construction site, there may be additional regulations which must be observed.

Connecting to a Building’s Electrical System

Connections for standby power to a building’s electrical system must be made by a qualified electrician. The connection must isolate the generator power from utility power or other alternative power sources and must comply with all applicable laws and electrical codes.

warning

Generator produces hazardous voltage.

Failure to isolate generator from power utility can result in death or injury to electric utility workers due to backfeed of electrical energy.

When using generator for backup power, notify utility company. Use approved transfer equipment to isolate generator from electric utility.

Use a ground fault circuit interrupter (GFCI) in any damp or highly conductive area, such as metal decking or steel work.

DO NOT touch bare wires or receptacles.

DO NOT use generator with electrical cords which are worn, frayed, bare or otherwise damaged.

DO NOT operate generator in the rain or wet weather.

DO NOT handle generator or electrical cords while standing in water, while barefoot, or while hands or feet are wet.

DO NOT allow unqualified persons or children to operate or service generator.

Generator Location

Clearances and Air Movement

warning

Exhaust heat/gases can ignite combustibles, structures or damage fuel tank causing a fire.

Keep at least 5 feet (1.5 m) of clearance on all sides of generator including overhead.

Place generator outdoors in an area that will not accumulate deadly exhaust gas. DO NOT place generator where exhaust gas (A) could accumulate and enter inside or be drawn into a potentially occupied building. Ensure exhaust gas is kept away from any windows, doors, ventilation intakes, or other openings that can allow exhaust gas to collect in a confined area. Prevailing winds and air currents should be taken into consideration when positioning generator.

A

11

Page 11
Image 11
Milwaukee 4960-24 System Ground, Connecting to a Building’s Electrical System, Generator Location, Special Requirements

4960-24, 4970-24 specifications

The Milwaukee 4960-24 and 4970-24 are powerful tools from Milwaukee's renowned lineup, specifically designed to meet the demands of professional tradespeople and DIY enthusiasts alike. These models are standout products in the company's commitment to durability, innovation, and user-friendly features that make them indispensable on the job site and in home improvement projects.

One of the main features of the Milwaukee 4960-24 and 4970-24 is their robust motor design. Both models are equipped with high-performance brushless motors that provide extended runtime and more efficient operation. This advanced motor technology not only ensures durability but also enhances the overall power output, allowing users to tackle even the toughest tasks with confidence.

The Milwaukee 4960-24 focuses on versatility, featuring a compact and lightweight design that makes it easy to maneuver in tight spaces. With an adjustable speed setting, it can accommodate a wide range of applications, from heavy-duty cutting to more delicate precision work. The ergonomically designed handle provides comfort during extended use, reducing fatigue and promoting productivity.

In contrast, the Milwaukee 4970-24 offers an augmented level of performance suited for more demanding applications. With a higher horsepower rating and enhanced torque, this model is ideal for heavy-duty cutting, grinding, and sanding tasks. Its rugged construction is built to withstand the rigors of job site conditions, featuring reinforced housings and robust components designed for long-lasting performance.

Both models boast advanced battery technologies, compatible with Milwaukee's M18 battery system. This compatibility allows users to interchange batteries across a wide selection of Milwaukee tools, improving efficiency and reducing downtime. Additionally, the intelligent battery management system optimizes performance, ensuring that users get the most out of their tools without the frustration of sudden power loss.

Incorporating user-friendly features, such as tool-free blade changes and integrated LED work lights, the Milwaukee 4960-24 and 4970-24 prioritize ease of use. These tools help enhance visibility in dimly lit workspaces and provide quick adjustments, catering to the needs of professionals who require flexibility and efficiency on the job.

In summary, the Milwaukee 4960-24 and 4970-24 are exceptional tools that embody the brand's dedication to quality, performance, and innovation. With their advanced motor technology, robust design, and thoughtful user features, these models exemplify what modern power tools should offer, making them valuable assets for users in various trades and applications.