DS VISION 3000
Figure 18 shows a Line Splitter L cascaded to a Receiver DCL.
Player  | 
  | 
  | Receiver  | 
  | 
  | 300m/1,000ft  | DCL  | 
  | 
  | 
  | |
200m/660ft  | 100m/330ft  | 
  | Receiver  | 
  | Receiver DCL  | 300m/1,000ft  | DCL  | 
Transmitter/Broadcaster  | Line Splitter Long  | 
  | |
  | 
  | 
  | 
Figure 18 Receiver DCL + Line Splitter L
Figure 19 shows two Receiver DCL units cascaded to 300m/1,000ft. (You can cascade up to 10 levels of Receiver DCL / Line Splitters).
Player
Receiver DCL
100m/330ft
Transmitter/Broadcaster
Receiver DCL
200m/660ft
Figure 19 Cascaded Receivers DCL
6. Pre-installation  guidelines
Place cables away from fluorescent lights, air conditioners, and machines that are likely to generate electrical noise.
Twisted Pair wiring - installation tips
∙The minimum recommended bend radius for Twisted Pair cable is 4 cm.
∙Don’t twist the Twisted Pair cable.
∙Don’t over tighten wire ties.
∙Don’t bend the Twisted Pair cable more than 90 degrees.
∙Don’t use a stapler for installation.
∙Don’t stretch or apply a 
13