Miranda Camera Co JAZZ-800 manual Panel - Section, Orange Orange, Blue Off

Models: JAZZ-800

1 114
Download 114 pages 49.7 Kb
Page 39
Image 39
Panel – Section 10

GUIDE TO INSTALLATION AND OPERATION

Panel – Section 10

NOTE: REM/TALLY status has GPI interface (GPI pins 7 and 8) for ON-AIR indication

PANL LOCK (Button) – Locks the Local Control Panel. To activate the PANEL LOCK, press and hold the button for 2 seconds.

Button Color

Orange

Orange

State

Mode

Comments

Solid

Active

Control panel operative – press & hold 2 sec. to LOCK PANEL

Flashing

Active

Control panel locked – press & hold 2 sec. to UNLOCK PANEL

Note: When the panel is locked, it will still update to show current status.

Power Switch – Inhibits both power supplies in the JAZZ-800 chassis (This control is not active when the panel is used in the remote configuration.)

Color

Blue

Off

State

Mode

Comments

Solid

Active

Power On

n/a

All

Power off

REM – TALLY (Button) - Not functional / Future expansion

JAZZ-800 35

Page 39
Image 39