Mitsubishi Electronics HC3100 EN-25, INSTALLATION menu, English, Auto Power Off, OFF / 5 - 60min

Models: HC3100

1 41
Download 41 pages 57.42 Kb
Page 25
Image 25
2. INSTALLATION menu

2. INSTALLATION menu

 

ITEM

SETTING

FUNCTION

LAMP MODE

STANDARD

Select this option when you want to view images in a well-lit room.

 

LOW

Select to moderate the intensity of the lamp. The fan operating sound is reduced

 

 

and the lamp lifetime becomes longer.

LAMP TIME (LOW)

****H

This item shows a lamp operating time (hour) when LAMP MODE is LOW.

 

 

• When the LAMP MODE is STANDARD, this item shows a longer lamp operat-

 

 

ing time than the actual time. (See page 33 for the interval of lamp replace-

 

 

ment.)

CW SPEED

4x / 5x

Use to change the rotation speed of the color wheel. Select 4x for normal use.

 

 

See page 30.

AUTO POWER ON

ON / OFF

When ON is chosen, the lamp is automatically lit when the power cord is plugged

 

 

in the wall outlet. Choose ON when using the projector mounted on the ceiling.

 

 

• The projector is in the stand-by mode when the lamp is off. Use the remote

 

 

control to turn on the lamp.

AUTO POWER OFF

OFF / 5 - 60min

Use to set the time elapsed before the projector enters the stand-by mode when

 

 

there is no signal input from the source.

SPLASH SCREEN

ON / OFF

Choose ON to display the splash screen when the power is turned on.

BACK COLOR

BLUE / BLACK

Use to change the color of the screen that appears when no signal is supplied.

IMAGE REVERSE

OFF

Select when viewing images from the front with the projector installed on the

 

 

floor.

 

MIRROR

Select when viewing images projected from the behind of the screen with the

 

 

projector installed on the floor.

 

INVERT

Select when viewing images projected from the behind of the screen with the

 

 

projector installed on the ceiling.

 

MIRROR INVERT

Select when viewing images from the front with the projector installed on the

 

 

ceiling.

TRIGGER OUT

ON / OFF

Choose ON to output the trigger output signal (12 V) from the TRIGGER terminal

 

 

when the lamp illuminates.

TEST PATTERN CROSS HATCH

Select to show the test cross hatch pattern.

 

WHITE

Select to show the maximum brightness image.

 

BLACK

Select to show the minimum brightness image.

When LAMP MODE has been set to LOW, the lamp mode changes from STANDARD to LOW about one minute after turn-on.

When the lamp mode is switched, the projected image may flicker. This is not a product malfunction.

Do not change the setting of LAMP MODE frequently.

To cancel the test pattern, press any button.

ENGLISH

EN-25

Page 25
Image 25
Mitsubishi Electronics HC3100 user manual EN-25, INSTALLATION menu, English, Auto Power Off, OFF / 5 - 60min