20. BALANCE Gain Data

Function

The external control equipment changes the BALANCE gain data of the plasma monitor.

Transmission Data

DFH

80H

60H

7FH

03H

DATA00

DATA01 DATA02 CKS

DATA00:

USER PICTURE Gain Flag

05H

DATA01:

BALANCE Gain Flag

 

02H

DATA02:

BALANCE Gain

 

 

EAH: -22

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FFH: -01

 

 

 

 

 

 

00H: 0

 

 

 

 

 

 

01H: +01

 

 

 

 

 

 

 

 

 

 

 

 

 

 

16H: +22

ACK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7FH

60H

80H

7FH

02H

DATA00 DATA01 CKS

DATA00:

USER PICTURE Gain Flag

05H

DATA01:

BALANCE Gain Flag

 

02H

21. SCREEN MODE Select

Function

The external control equipment switches the screen mode of the plasma monitor.

Transmission Data

DFH 80H 60H 51H 01H DATA00 CKS

DATA00: 02H: STADIUM 03H: ZOOM

04H: NORMAL

05H: FULL

06H: TRUE (REAL)

ACK

7FH 60H 80H 51H 01H DATA00 CKS

DATA00: 02H: STADIUM 03H: ZOOM

04H: NORMAL

05H: FULL

06H: TRUE (REAL)

22. V. POSITION Gain Data

Function

The external control equipment changes the V. POSITION gain data of the plasma monitor.

Transmission Data

DFH

80H

60H

7FH

03H

DATA00

DATA01 DATA02 CKS

DATA00:

USER PICTURE Gain Flag

03H

DATA01:

V. POSITION Gain Flag

 

01H

DATA02:

V. POSITION Gain

 

 

C0H: -64

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FFH: -01

 

 

 

 

 

 

00H: 0

 

 

 

 

 

 

01H: +01

 

 

 

 

 

 

 

 

 

 

 

 

 

 

40H: +64

ACK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7FH

60H

80H

7FH

02H

DATA00 DATA01 CKS

DATA00:

USER PICTURE Gain Flag

03H

23. H. POSITION Gain Data

Function

The external control equipment changes the H. POSITION gain data of the plasma monitor.

Transmission Data

DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS

DATA00:

USER PICTURE Gain Flag

03H

DATA01:

H. POSITION Gain Flag

02H

DATA02:

H. POSITION Gain

80H: -128

FFH: -01

00H: 0

01H: +01

7FH: +127

ACK

7FH 60H 80H 7FH 02H DATA00 DATA01 CKS

DATA00:

USER PICTURE Gain Flag

03H

DATA01:

H. POSITION Gain Flag

02H

24. V-HEIGHT Gain Data

Function

The external control equipment changes the V-HEIGHT gain data of the plasma monitor.

Transmission Data

DFH

80H

60H

7FH

03H

DATA00 DATA01 DATA02 CKS

DATA00:

USER PICTURE Gain Flag

03H

DATA01:

V-HEIGHT Gain Flag

 

07H

DATA02:

V-HEIGHT Gain

 

 

00H: 0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

40H: +64

ACK

 

 

 

 

 

 

 

 

 

 

 

 

 

7FH

60H

80H

7FH

02H

DATA00 DATA01 CKS

DATA00:

USER PICTURE Gain Flag

03H

DATA01:

V-HEIGHT Gain Flag

 

07H

25. H-WIDTH Gain Data

Function

The external control equipment changes the H-WIDTH gain data of the plasma monitor.

Transmission Data

DFH

80H

60H

7FH

03H

DATA00 DATA01 DATA02 CKS

DATA00:

USER PICTURE Gain Flag

03H

DATA01:

H-WIDTH Gain Flag

 

08H

DATA02:

H-WIDTH Gain

 

 

00H: 0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

40H: +64

ACK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7FH

60H

80H

7FH

02H

DATA00 DATA01 CKS

DATA00:

USER PICTURE Gain Flag

03H

DATA01:

H-WIDTH Gain Flag

 

08H

46

Page 52
Image 52
Mitsubishi Electronics PD-5010 Balance Gain Data, Screen Mode Select, 22. V. Position Gain Data, 23. H. Position Gain Data