Indicators

This projector has 2 indicators, each of which shows the operation condition of the projector.

The following offer solutions to possible problems. If these problems persist, turn the projector off and consult your dealer.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

POWER indicator

Normal condition

 

 

STATUS indicator

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

POWER

STATUS

CONDITION

NOTE

 

 

 

 

 

 

 

 

 

 

 

 

Steady

 

Off

Stand-by

 

 

 

 

 

 

 

 

red

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Lamp stand-by for power-on (about 1 minute)

The power cannot be turned off by pressing

 

 

 

 

 

 

 

 

 

 

 

the POWER button.

 

 

 

 

 

 

 

 

 

 

 

Steady

Blinking

 

 

 

 

 

 

 

 

 

 

 

Lamp stand-by for power-off (about 2 minutes)

 

green

green

For the first one minute, the power cannot be

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

turned on by pressing the POWER button.

 

 

 

 

 

 

 

 

 

 

 

 

Steady

Steady

The power is on. (Normal condition)

 

 

 

 

 

 

 

green

green

 

 

 

 

 

 

Abnormal condition

 

POWER

STATUS

CONDITION

POSSIBLE SOLUTION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Abnormal temperature

 

Steady

 

 

 

 

 

• The ventilation grilles are clogged with dust or dirt.

• Clean the ventilation grilles.

green

 

 

 

 

 

• The room temperature is high.

• Relocate the projector to a cooler place.

or

 

 

 

 

 

 

 

 

 

 

 

Blinking orange

 

 

 

 

 

 

Steady red

 

 

 

 

 

 

 

 

 

 

 

The protection circuit is working or the lamp is in an abnormal condition.

Steady red

Blinking green

Wait until the STATUS indicator goes out, then press the POWER button.

If the above solution is not effective, replace the lamp.

 

 

 

 

 

 

 

 

 

 

The lamp operation time exceeds the time elapsed until the

Replace the lamp.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Steady

Blinking green/red

lamp shutdown notice while the power is on. (See page 38.)

Change with a new lamp if this problem

green

 

 

 

 

 

 

recurs.

 

 

 

 

 

 

 

 

 

 

The lamp operation time exceeds the time elapsed until the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Steady red

Blinking red

lamp shutdown notice while the power is off. (See page 38.)

 

 

 

 

 

 

 

 

 

 

 

The lamp operation time exceeds the time elapsed until the

 

Steady red

Steady red

lamp shutdown. (See page 38.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Off

The lamp cover isn’t closed.

Close the cover correctly.

 

 

 

 

 

 

Blinking

 

 

 

 

 

 

 

 

 

 

green/red

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Abnormal.

Contact your dealer.

 

 

 

 

 

Steady

 

 

 

 

 

 

 

 

 

Blinking

 

 

or

 

 

 

 

 

 

 

 

 

green/red

 

 

 

 

 

 

 

Blinking

 

 

 

 

 

 

 

 

 

EN-37