IMPORTANT SAFETY INFORMATION
Continued from page 3
10.This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.
11.Do not place propane/LP supply tank(s) inside any struc- ture. Locate propane/ LP supply tank(s) outdoors.
12.If you smell gas
•shut off gas supply
•do not try to light any appliance
•do not touch any electrical switch; do not use any phone in your building.
•immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions
•if you cannot reachyour gas supplier, call the fire depart- ment
13.This heater shall not be installed in a bedroom or bath- room.
14.This heater needs fresh, outside air ventilation to run properly. This heater has an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS shuts down the heater if not enough fresh air is available. See “Air For Combustion and Ventilation,” pages 8 through 10.
15.Before using furniture polish, wax, carpet cleaner, or similar products, turn heater off. If heated, the vapors from these products may create a white powder residue within burner box or on adjacent walls or furniture.
16.If heater shuts off, do not relight until you provide fresh, outside air. If heater keeps shutting off, have it serviced.
17.Do not run heater
•where flammable liquids or vapors are used or stored.
•under dusty conditions.
18.Do no t use heater if any part has been under water. Imme- diately call a qualified service technician to inspect the room heater and to replace any part of the control system and any gas control which has been under water.
19.To prevent the creation of soot, follow the instructions in “Cleaning and Maintenance,” page 26.
20.Turn off and unplug heater and let cool before servicing. Only a qualified service person should service and repair heater.
21.Operating heater above elevations of 4,500 feet could cause pilot outage.
22.To prevent performance problems, do not use a propane/ LP fuel tank of less than 100 lbs. capacity.
23.This unit complies with ANSI
24.Caution: Candles, incense, oil lamps, etc. produce com- bustion byproducts including soot.
25.Unvented gas heaters emit moisture into the living area. In most homes of average construction, this does not pose a problem. In houses of extremely tight construction, additional mechanical ventilation is recommended.
26.During manufacturing, fabricating and shipping, various components of this appliance are treated with certain oils, films or bonding agents. These chemicals are not harmful but may produce annoying smoke and smells as they are burned off during the initial operation of the appliance; possibly causing headaches or eye or lung irritation. This is a normal and temporary occurrence.
The initial
27.The appliance and its appliance main gas valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa).
28.The appliance must be isolated from the gas supply piping system by closing its equipment shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.5 kPa).
29.This appliance is not a zero clearance fireplace. Do not frame this fireplace into a wall.
4 | 49D0090 |