SPECIFICATIONS AND LOCAL CODES

SPECIFICATIONS AND LOCAL CODES

NATURAL GAS

NOTE: An external regulator is required to reduce supply pressure to a maximum of 101/2" W.C. on natural gas systems operating at higher pressure.

Thermostat Pressure

Regulator Pressure Setting: 4" w.c.

Gas Inlet Pressure: 101/2" w.c. Min. 5" w.c.

 

 

Gas Rate
Model Number

Control

Max BTU/Hr

Min BTU/Hr

DHHNT

THERMOSTAT

30,000

15,000

PROPANE/LPG

Note: An external regulator is required to reduce supply pressure to a maximum of 13" W.C.

Thermostat Pressure

Regulator Pressure Setting: 10" w.c.

Gas Inlet Pressure: Max. 13" w.c. Min. 11" w.c.

 

 

Gas Rate

Model Number

Control

Max BTU/Hr

Min BTU/Hr

DHHPT

THERMOSTAT

30,000

15,000

LOCAL CODES

Follow all local codes. In the absence of local codes, use the latest edition of The National Fuel Gas Code, ANS Z223.1, also known as NFPA 54. Available from: