Monessen Hearth BTU/Hr Lighting Instructions, Do not try to adjust heating levels by

Models: BTU/Hr

1 32
Download 32 pages 22.31 Kb
Page 20
Image 20
LIGHTING INSTRUCTIONS

OPERATING INSTRUCTIONS

LIGHTING INSTRUCTIONS

1.STOP! Read the safety information label.

2.Make sure the manual shutoff valve is fully open.

3.This gas log set is equipped with an ignition device (piezo) which automatically lights the pilot. If piezo ignitor does not light the pilot, refer to instructions for “Match Lighting Instructions”, page 21.

4.Turn gas control knob clockwise Do not try to adjust heating levels byto the OFF position.

5.Wait (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow the instructions under “What To Do if You Smell Gas,” page 17. If you don't smell gas, go to next step.

6.From OFF position, turn the gas control knob counterclockwiseusing the equipment shutoff valve. to PILOT position. Push in control knob for 5 seconds. See Figure 20. NOTE: If you are running the heater for the first time, it will be necessary to press in the control knob for 30 seconds or longer to allow air to bleed out of the gas piping.

7.With control knob pressed in, push down and release ignitor button. This will light pilot. The pilot is attached to the front of burner. If needed, keep pressing ignitor button until pilot lights. Note: If pilot does not stay lit, refer to “Troubleshooting,” pages 32 through 25. Also contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see “Match Lighting Instructions,” page 21.

8.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

If control knob does not pop up when released, contact a qualified service person or gas supplier for repairs.

Note: If pilot goes out, repeat steps 4 through 8 . This heater has a safety interlock system. Wait one (1) minute before lighting pilot again.

9.Turn control knob counterclockwise counterclockwise Manual background to desired heating level. The main burner should light. Set control knob to any heat level between HI and LO. For thermostat operation, see page 21.

WARNING

Do not try to adjust heating levels by

 

 

using the equipment shutoff valve.

 

Control

 

Knob

 

 

 

 

 

 

 

Piezo

 

Ignitor

Figure 18 - Control Knob In The OFF Position

Thermocouple (LP only)

Ignitor Electrode

Pilot Burner

Thermocouple Manual background

(NG only)

Figure 19 - Pilot

20

49D0090

Page 20
Image 20
Monessen Hearth BTU/Hr Lighting Instructions, Do not try to adjust heating levels by, using the equipment shutoff valve