VENTILATION AIR

FRESH AIR FOR COMBUSTION AND VENTILATION

VENTILATION AIR

FROM INSIDE BUILDING

This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you must provide two permanent openings: one within 12" of the ceiling and one within 12" of the floor on the wall connecting the two spaces (see options 1 and 2, Figure 6). You can also remove door into adjoining room (see option 3, Figure 6). Follow the National Fuel Gas Code, NFPA 54/ ANSI Z223.1, Section 5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts.

Option 1:

 

Ventilation

Option

Grills into

3:

Adjoining

Remove

Room

Door into

 

 

Adjoining

 

Room

���

Option 2:

Ventilation Grills into

Adjoining Rooms

���

WARNING

Rework worksheet, adding the space of the adjoining unconfined space. The combined spaces must have enough fresh air to supply all appliances in both spaces.

Figure 6 - Ventilation Air from Inside Building

VENTILATION AIR FROM OUTDOORS

Provide extra fresh air by using ventilation grills or ducts. You must provide two perma- nent openings: one within 12" of the ceiling and one within 12" of the floor. Connect these items directly to the outdoors or spaces open to the outdoors. These spaces include attics and crawl spaces. Follow the National Fuel Gas Code, NFPA 54/ANSI Z223.1, Section 5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts.

IMPORTANT: Do not provide openings for inlet or outlet air into attic if attic has a thermostat-controlled power vent. Heated air entering the attic will activate the power vent.

Outlet

Air

Outlet

Air

Ventilated

Outlet Attic

Air

To Attic

To

Crawl

Space

 

 

 

 

Inlet Air

 

 

 

Ventilated

 

 

 

 

 

 

 

 

 

 

 

 

Crawl Space

 

 

 

 

Figure 7 - Ventilation Air from Outdoors